Trimline Opal
Installation instruction
3
1 GENERAL INSTRUCTIONS
NOTE
The installation may only be carried out by an authorised
person.
•
The appliance must be installed, connected, inspected
and serviced as a closed appliance by a qualified fitter,
according to local standards and regulations.
•
The flue tube system and the outlets in the outer wall or
roof face must also meet the requirements outlined in
the applicable local standards and regulations.
•
The temperature of the walls near the side and back of
the appliance may not exceed the ambient temperature
by 60 K or more. For example, ambient temperature 20 °C,
maximum increase of 60 K gives a maximum temperature
of 80 °C.
•
The appliance has been approved in combination with
the concentric flue system THC/Holetherm in accordance
with European CE standards for gas appliances, and may
therefore only be applied with this system.
•
The appliance needs to be inspected by the fitter for local
gas distribution (gas type and gas pressure) as indicated
on the identification plate.
•
The instructions are only applicable if the relevant country
code is stated on the appliance.
•
There will be air in the gas pipes when the appliance is first
used. The gas supply pipes therefore need to be vented
first. The glass panel must not be in place when venting
and igniting the first time.
•
Ignite the appliance according to the user manual and check
the flame is burning evenly. After the appliance has been
used for the first time, any deposits resulting from curing
must be removed from the glass panel using a glass cleaner
made specifically for fireplaces.
Distance to flammable materials
Maintain the following minimum distances from combustible
materials: front 1000mm, side 500mm, top 1200mm to
curtains, fabrics and/or combustible material. Maintain
a minimum distance of 50mm from the back wall.
Distance to non-flammable materials
The appliance needs to be placed a minimum distance
of 25mm from the wall unless stated otherwise in these
instructions.
WARNING
•
Gas fires become hot when in use. After installation of the
appliance, the glass panel surface is considered to be an
active zone. The glass panel surface can become very hot.
•
Therefore, you should take care by, for example, keeping
children and those requiring help away from the immediate
vicinity of burning fires. Gas fires must not be placed on or
against flammable materials.
2 PLACING THE APPLIANCE
NOTE
Before installing the appliance, please read Chapter
8 Concentric flue system
.
Option
If you want to install an LED glow bed module, first review
Chapter
11 Installing the optional LED glow bed module
.
2.1 Preparation and installation
•
Check the packaging for damage. Remove the packaging
and check the contents are intact and complete. Report
damage and defects to the supplier immediately.
•
The packaging contains the following components:
-Appliance
-Remote control
-Ceramic wood set
- dispersion medium
(glass granules and
coal embers)
-restrictor
(top connection)
-restrictor
(rear connection)
-baffle plate
(rear connection)
-4 x AA battery
-2 x AAA battery
-Installation instruction
-User Manual
3/8” connection point