background image

 

Trimline Opal

Installation instruction

3

1  GENERAL INSTRUCTIONS

 NOTE

The installation may only be carried out by an authorised 
person.

 

The appliance must be installed, connected, inspected 
and serviced as a closed appliance by a qualified fitter, 
according to local standards and regulations.

 

The flue tube system and the outlets in the outer wall or 
roof face must also meet the requirements outlined in 
the applicable local standards and regulations.

 

The temperature of the walls near the side and back of 
the appliance may not exceed the ambient temperature 
by 60 K or more. For example, ambient temperature 20 °C, 
maximum increase of 60 K gives a maximum temperature 
of 80 °C.

 

The appliance has been approved in combination with 
the concentric flue system THC/Holetherm in accordance 
with European CE standards for gas appliances, and may 
therefore only be applied with this system.

 

The appliance needs to be inspected by the fitter for local 
gas distribution (gas type and gas pressure) as indicated 
on the identification plate.

 

The instructions are only applicable if the relevant country 
code is stated on the appliance.

 

There will be air in the gas pipes when the appliance is first 
used. The gas supply pipes therefore need to be vented 

first. The glass panel must not be in place when venting 
and igniting the first time.

 

Ignite the appliance according to the user manual and check 
the flame is burning evenly. After the appliance has been 
used for the first time, any deposits resulting from curing 
must be removed from the glass panel using a glass cleaner 
made specifically for fireplaces.

Distance to flammable materials

Maintain the following minimum distances from combustible 
materials: front 1000mm, side 500mm, top 1200mm to 
curtains, fabrics and/or combustible material. Maintain 
a minimum distance of 50mm from the back wall.

Distance to non-flammable materials

The appliance needs to be placed a minimum distance 
of 25mm from the wall unless stated otherwise in these 
instructions.

 WARNING

 

Gas fires become hot when in use. After installation of the 
appliance, the glass panel surface is considered to be an 
active zone. The glass panel surface can become very hot.

 

Therefore, you should take care by, for example, keeping 
children and those requiring help away from the immediate 
vicinity of burning fires. Gas fires must not be placed on or 
against flammable materials.

2  PLACING THE APPLIANCE

 NOTE

Before installing the appliance, please read Chapter 

8 Concentric flue system

.

Option

 

If you want to install an LED glow bed module, first review 
Chapter 

11 Installing the optional LED glow bed module

.

2.1  Preparation and installation

 

Check the packaging for damage. Remove the packaging 
and check the contents are intact and complete. Report 
damage and defects to the supplier immediately.

 

The packaging contains the following components:

 -Appliance
 -Remote control
 -Ceramic wood set
 - dispersion  medium 

(glass granules and 
coal embers)

 -restrictor 

  (top connection)

 -restrictor

 

(rear connection)

 -baffle plate 

  (rear connection)

 -4 x AA battery
 -2 x AAA battery
 -Installation instruction
 -User Manual

3/8” connection point

Содержание Trimline Opal 1121

Страница 1: ...Trimline Opal 1121 INSTALLATION INSTRUCTION GBR IRL...

Страница 2: ...BURNER MESH AND DISPERSION MEDIUM 9 4 TECHNICAL DETAILS MAXITROL GV60 11 5 INSTRUCTIONS FOR MAXITROL GV60 12 6 GAS TECHNICAL SPECIFICATIONS 14 7 CONCENTRIC PATHWAYS 16 8 CONCENTRIC FLUE SYSTEM 17 8 1...

Страница 3: ...he first time any deposits resulting from curing must be removed from the glass panel using a glass cleaner made specifically for fireplaces Distance to flammable materials Maintain the following mini...

Страница 4: ...the mantle and the floor to 70mm 2 3 Connection to the gas supply pipes You can determine where the gas supply pipes will be placed dependent on the layout Ensure control equipment is not twisted dur...

Страница 5: ...ough the slotted holes to which the covers attach Loosen the bolts 2 on the left and 2 on the right a few turns but do not remove them Remove the glazing bars at the bottom and top by removing the 8 n...

Страница 6: ...so be connected to the rear Proceed as follows to convert the unit to this arrangement Remove the glass panel see paragraph 2 4 Glass panel removal If necessary remove the baffle and restrictor see pa...

Страница 7: ...n the rear 5 At the front the baffle plate and possibly the restrictor still need to be installed Remove the breakout plate from the rear wall 6 There is no need to remove the rear wall from the appli...

Страница 8: ...describes when a baffle plate and or a restrictor must be fitted This is important to ensure the gas fire works correctly 2 7 Refitting the glass panel Carefully push the glass panel into place in a s...

Страница 9: ...ng the appliance Remove the right hand part of the grille Remove the right burner 2 Distribute the glass granules evenly over the middle part of the grille Place the middle log A on the horizontal bur...

Страница 10: ...3 5 2 4 6 7 A A A B F F G G Trimline Opal Installation instruction 10...

Страница 11: ...er 5 Gas outlet front burner middle burner 6 Multi cable 7 Piezo connection 8 Connector double burner 9 Receiver Appliance category C11 C31 C91 Pilot flame SIT 3 flames Security Thermocouple principle...

Страница 12: ...cuit of the antenna This could mean the appliance becomes less responsive or totally unresponsive to commands from the handset NOTE Do not tighten the contact breaker and the thermocouple connection t...

Страница 13: ...Trimline Opal Installation instruction 13 NOTE In the event of an emergency the I 0 switch can be used to switch off the appliance The I 0 switch is located behind the bottom cover...

Страница 14: ...m temperature by thermostat No With electronic control of room temperature Yes With electronic control of room temperature plus day time switch Yes With electronic control of room temperature plus wee...

Страница 15: ...room temperature control No 2 or more manually adjustable stages no control of the room temperature No With mechanical control of room temperature by thermostat No With electronic control of room tem...

Страница 16: ...horizontal X X1 X2 Y 2 1 Ratio vertical horizontal X X1 Y 2 1 Restriction conditions all gas types Distance Baffle plate Restriction G20 and G20 25 Vertical lay out 1 6m Yes 35mm 6 12m Yes 45mm G25 3...

Страница 17: ...instructions The correct restrictor will provide the appliance with the most optimal efficiency flame image and combustion Mounting an incorrectly placed restrictor may cause malfunction of the appli...

Страница 18: ...s among other things that the chimney pass through must not be smaller than 150mm round square but no larger than 200mm and not ventilated by grilles etc In the case of larger chimney pass throughs a...

Страница 19: ...der a carport roof or balcony inside and outside corners 500 G From ground level and rainwater drainage pipes 300 H Inside and outside a corner 500 I Above an external gas pressure regulator 1000 Side...

Страница 20: ...ars A check must be carried out on 1 seal of the flue and supply circuits 2 seal of the upper and lower pressure release hatches of the appliance check the gasket 3 operation of the pressure release h...

Страница 21: ...e glass panel on page 5 IMPORTANT After lighting for the first time a haze may form on the inside of the glass panel When the appliance has cooled down after the first use the glass must be cleaned im...

Страница 22: ...here must be a 230 VAC wall socket for the LED module power supply in the vicinity of the appliance 11 2 Fitting the glass plate Remove the front glass panel Paragraph 2 3 Removing the front glass pan...

Страница 23: ...n the left and right side the long glazing bars are fitting at the front and back do not forget to refit the air guide 7 Do not overtighten the screws this could risk glass breakage Refit the burners...

Страница 24: ...est method is to push the LED unit as far back as possible initially against the back wall of the mantle Secure the LED unit with the two screws 1 Remove the receiver from the holder and attach the ca...

Страница 25: ...tal Check whether cable is free of metal parts Poor spark candle Check spark candle for fractures replace if necessary Distance of sparkling candle to pilot flame head Check distance is approximately...

Страница 26: ...me should be free of obstructions Small lazy pilot flame Check and correct pressure and physical state of pilot flame burner Close main burner flame openings Check and clean with a vacuum cleaner or s...

Страница 27: ...110 303 206 176 1074 500 100 150 13 73 540 550 235 430 70 176 1325 205 303 100 150 100 500 75 75 50 500 Trimline Opal Installation instruction 27 Appendix 1 DIMENSIONAL DRAWINGS Trimline Tourmaline M...

Страница 28: ...r stoves with a closed combustion system Chimney mounting plate Renovation package Existing flue Clamping strap Roof pass through Clamping strap Interior mounting plate Renovation package Sliding elem...