9 PASS-THROUGH POSITIONS AND FUNCTION CORRECTLY
Dimensions Outlet positions
Distance mm
A
Distance to ventilation openings
Room*
B
Distance to ventilation openings
Room*
C
Distance to ventilation openings
Room*
D
Lower gutter bottom pipes or exhaust lines
500
E
Under the eaves
500
F
Under a carport, roof or balcony, inside and outside corners
500
G
From ground level and rainwater drainage pipes
300
H
Inside and outside a corner
500
I
Above an external gas pressure regulator
1000
Side of a gas pressure regulator
500
J
Conflict distance façade outlet
Room*
K
Roof drain centre to centre
1000
L
From the centre of both roof drains
450
M
Two wall drains above each other
1000
N
Two wall drains next to each other
1000
* In accordance with local building codes
Plot boundary
External extension pipe
Roof pass-through