“LIVELINK INSTALL” APP / ROOM ADMINISTRATION / ROOM SETUP: OPTION “SETTING UP SCENES”
Page 58 / 77
Constant light control: Setting the offset
For a uniform and efficient illumination, it may be
sensible to undertake a separate control of luminaires
that are close to the window and that are far from
the window.
If only one sensor is available, an offset setting may
be applied:
Once the constant light control has been activated,
the luminaires that are linked to this function are
marked in colour. By tapping the luminaire groups,
these can be activated and/or deactivated and as
such different target values can be set.
Caution: The target values are set for the condition of
maximum incident daylight. If daylight is available
during the setup, the target values can be adjusted
optimally while observing the light distribution. If
no daylight is available, the target values must be
estimated.
Caution: For separate control of luminaires close
to the window and luminaires far from the window,
an individualised control with multiple sensors that
adjust the different luminaire groups separately is
better suited.