Access Point Deployment Guide
41
NOTICE: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc.,
its subsidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set
forth in the agreement between your company and Trilliant. The contents may not be used or disclosed without the
express written consent of Trilliant.
Field
Unit
Description
Reuse Code
Decimal
Different Reuse Codes allow two APs to operate on the same Channel and System
ID without interference. Range is 0 – 255.
Center
Frequency
MHz
This field is not editable. The value for center frequency is determined from the
setting for the Channel field.
Broadcast Gold
Code
Hex
This field is not editable. The value for the broadcast gold code is determined from
the information provided in the following fields:
•
System ID
•
Channel
•
Reuse Code
Max Uplink
PDUs
Decimal
The maximum number of PDUs allowed on the uplink. Range is 4 –512. The
default setting is 16.
UL Overload
Alarm
Threshold
dBm
This alarm triggers when the threshold for uplink capacity has been reached. Range
is 0 – 31.
Interference
Alarm
Threshold
dBm
This alarm triggers when the threshold for interference on the uplink has been
reached. Range is 0 – 31.
Field Config Submenu
The Field Configuration screen (shown below) displays configuration parameters that were set at
the time the AP was deployed.