Product manual EM converterLED ST | 08-2018 | 1.0 | en
Determining light output in emergency operation
c
24 / 38
1.
2.
3.
To determine the light output in emergency operation the following parameters are crucial:
LED forward voltage (total forward voltage of all connected LED modules)
LED current in emergency operation
Light output in emergency operation
7.1. Parameter 1: LED forward voltage
7.1.1. Total forward voltage of all LED modules
The forward voltage of a single LED module can be found in the data sheet. When calculating the total forward voltage of all LED
modules, series and parallel circuits must be handled differently:
Series circuit
Parallel circuit
The values of the individual LED modules are summed up.
The total value is the same as the value of a single LED module.
...
The total forward voltage of all connected LED modules must be within the forward voltage range of the EM converterLED ST
_