120 VAC +/- 10% 60Hz
15 Amps RMS
1800W
<40dB
<1W at 120VAC, 60Hz 

3.3V & Optically Isolated
4 ft. 

(1.2 meters)

2 Always ON 
 
5 Switched Outlets 

Ground, Surge, Switched
72,000 Amps / 1080 Joules for all 
outlets 

(Ceramic Surge Protection)

15A Resettable Circuit Breaker

www.tricklestar.com

The best way to save energy is to stop wasting it. 

TM

 

 

 

  

 

 

 

 

ELECTRICAL SPECIFICATIONS

PHYSICAL SPECIFICATIONS

ORDER INFORMATION

APPROVALS

TIER 2 APS+

MULTI SENSOR

FOR INDOOR USE
Operating Voltage
Output Current
Maximum Total Load
Noise Filtering
Power Consumption

RJ11
APS+ Cord Length
Outlets (7 Outlets)

LED Status Indication
Surge Protection

Input Current

FOR INDOOR USE
Voltage
IR Detection Angle/Range
PIR Detection Angle/Range
RF Detection Range
Cord Length
Sensor Detection

Operating Temperature
Storage Temperature
Humidity
IP Rating

TS1811

(1 outlet transformer spaced)

3.3V
60

°/

Up to 16.4 ft. (5 meters) 

90°/Up to 16.4

 ft.

 (5 meters)

360°/Up 16.4

 ft.

 (5 meters)

8

 ft.

Infrared, Passive Infrared
and ZigBee RF4CE 

32

° to 113° F

14° to 140° F
5 to 90% N/C
IP20

7 Outlet APS+, 1080 Joules, 
4 ft. Cord, Auto Threshold, 
Zigbee Multi-Sensor, TAV-Link

TrickleStar

® is a registered trademarks of TrickleStar Ltd. All other trademarks are the property of their respective owners. The information in this document is subject to change without notice.

TrickleStar assumes no responsibility for any errors that may appear in this document.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

Copyright © TrickleStar. All rights reserved.

Conformity to product standards for safety and EMC
UL (US & Canada), 2002/95/EG (RoHs), 2002/96/EC (WEEE),
1999/5/EC (RTTE),  FCC Approved, ZigBee Certified 

 

SENSOR OPTICAL VIEW PATTERN

PIR & IR DETECTION PATTERN

REV 5 Jan 2016

0     3.28 ft.  6.56 ft.   9.84 ft.  13.12 ft. 16.40 ft.

0     

3.28 ft. 

6.56 ft.   

9.84 ft.  

13.12 ft. 

16.40 ft.

19.69 ft.

0     

3.28 ft.  

6.56 ft.   

9.84 ft. 

13.12 ft.  

16.40 ft.

19.69 ft.

19.69 ft.

16.40 ft.

13.12 ft.

9.84 ft. 

6.56 ft.  

3.28 ft. 

19.69 ft.

16.40 ft.

13.12 ft.  

9.84 ft.  

6.56 ft.   

3.28 ft.  

16.40 ft.  13.12 ft.  9.84 ft.  6.56 ft.  3.28 ft.  

(in all modes of operation)

(1 outlet transformer spaced)

RF Detection 
Range: 16.4 ft.
Degree: 360°

IR Detection 
Range: 16.4 ft.
Degree: 60°

PIR Detection 
Range: 16.4 ft.
Degree: 90°

ADVANCED 

POW

TIER 2 ZIGBEE

®

 MULTI-SENSOR

Changes or modifications not expressly approved by the party responsible for compliance could void

your authority to operate the equipment.

Содержание TS1811

Страница 1: ...ommands from the multi sensor to an HDMI port on the TV this feature is known as TAV Link and will result in placement of connected HDMI devices into a power saving state by high level commands KEY FEATURES 7 Outlets 2 Always On Outlets 1 outlet transformer spaced 5 Switched Outlets 1 outlet transformer spaced 15A resettable circuit breaker Auto threshold detection Intelligently adjusts to new equ...

Страница 2: ...ontrols It provides two way high speed communications which allow remote signals to transmit through cabinets obstacles walls and floors CEC Consumer Electronics Control is the control protocol found in HDMI STEP 1 Quickly press the pinhole pairing button located on the back of the multi sensor to trigger the pairing process A blue LED will flash for a period of 15 seconds indicating the multi sen...

Страница 3: ...re the property of their respective owners The information in this document is subject to change without notice TrickleStar assumes no responsibility for any errors that may appear in this document This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference re...

Страница 4: ... TrickleStar LLC 2016 All rights reserved TrickleStar is a registered trademark of TrickleStar Ltd All other trademarks are the property of their respective owners The information in this document is subject to change without notice TrickleStar assumes no responsibility for any errors that may appear in this document For technical support go to www tricklestar com or call 1 888 700 1098 ...

Страница 5: ...ar determines that the damage did not result from the occurrence or that no occurrence in fact took place the repair or replacement of the damaged devices is covered under a manufacturer s warranty TrickleStar determines that the connected devices were not used under normal operating conditions or in accordance with any labels or instructions The Product is not plugged directly into a receptacle T...

Страница 6: ...he occurrence or that no occurrence in fact took place the repair or replacement of the damaged devices is covered under a manufacturer s warranty TrickleStar determines that the connected devices were not used under normal operating conditions or in accordance with any labels or instructions The Product is not plugged directly into a receptacle The Product is daisy chained together in serial fash...

Страница 7: ...R signal from any remote must be received to switch on the switched outlets Alternatively press the button on the multi sensor to switch on switched outlets manually Make sure that the TV is plugged into the outlet with the green TV icon Make sure that the TV peripherals are connected to the green switched outlets except for TV The switched outlets will switch off after the TV has been switched of...

Страница 8: ...nected to the APS and RF or IR signal from any remote must be received to switch on the switched outlets Alternatively press the button on the multi sensor to switch on switched outlets manually Make sure that the TV is plugged into the outlet with the green TV icon Make sure that the TV peripherals are connected to the green switched outlets except for TV The switched outlets will switch off afte...

Страница 9: ...ated there is a grounding problem and you must contact an electrician to properly ground the socket Surge protection will not work with an improperly grounded outlet Surge LED When illuminated it indicates that the surge protection is functioning normally If this LED illuminates red or extinguishes at any time the Product was sacrificed to protect your devices and must be replaced 6 7 Switched Out...

Страница 10: ...t indicates that the Product is correctly grounded If not illuminated there is a grounding problem and you must contact an electrician to properly ground the socket Surge protection will not work with an improperly grounded outlet Surge LED When illuminated it indicates that the surge protection is functioning normally If this LED illuminates red or extinguishes at any time the Product was sacrifi...

Страница 11: ...ch to TV mode Note www tricklestar com Advanced Powerstrip Advanced PowerStrip Outlet 7 Operation Countdown Timer Setting Operation RF Remote Control and Pairing Operation Delete Paired RF Remote ControlAddress Step 1 To configure the countdown timer press and hold the button for 10 seconds until the red LED illuminates Then press Once for 30 minutes Twice for 60 minutes Three times for 120 minute...

Отзывы: