TrickleStar TS1811 Скачать руководство пользователя страница 10

Operation - TV Mode

Press any button on TV remote control 

to turn on the switched outlets.

Press power on TV remote control to 

turn on TV.

Use peripheral RF/IR remotes to turn 

on peripherals as needed.

Step 2

Step 1

Step 3

When  done  watching  TV  press  the 

power button on the TV remote to 

switch off the TV. 

All switched outlets will then 

automatically turn off after 1 minute.

Step 4

ON

OFF

www.tricklestar.com

Advanced Pow

Advanced 

Pow

Outlet 

7

Energy Saving

Countdown Timer Operation

  For the first 15/30/60 minutes - the multi-sensor senses for RF/IR only.

  For the next 15/30/60 minutes - the multi-sensor senses for RF/IR signal or 

 motion.

  If no RF/IR or motion has been sensed during the 30/60/120 minute countdown     

  period, the switched outlets will switch off automatically.

Switched Outlets

Switch On

User Switches

TV On

15/30/60 Min Countdown

 Timer

Starts

RF + IR Remote Control Button

Press Detected?

Next 

15/30/60 Min Countdown

Timer Starts

RF/IR or Motion

Detected

TV & Peripherals

Switch Off

No

No

Yes

Yes

ALERTS START

10 Min Before Countdown

Timer Expiry

Buzzer Sounds 3X

LED Flashes

Terms

IR 

IR Signal Sensor 

PIR Sensor

Motion 

Countdown Timer

Countdown Period

LED

Buzzer

Infrared signal, transmitted by a remote control

Multi-sensor senses for an IR command 

Multi-sensor

  uses  passive  Infrared  sensing  to 

detect movement

Motion detected by PIR

Time before the switched outlets are automatically 

switched off

30/60/120 minutes (default - 60 min.)

Red LED located in multi-sensor

When IR or motion is sensed, the LED will flash

Buzzer located in the multi-sensor

-

RF 

Radio frequency, transmitted by a remote control

-

-

-

-

-

-

-

-

-

User Presses RF/IR

Remote Control

4

5

Ground LED

When illuminated, it indicates that the Product is correctly grounded.

If not illuminated, there is a grounding problem and you must contact an 

electrician to properly ground the socket. Surge protection will not work 

with an improperly grounded outlet.

Surge LED 

When  illuminated,  it  indicates  that  the  surge  protection  is  functioning 

normally. If this LED illuminates red or extinguishes at any time, the 

Product was sacrificed to protect your devices and must be replaced.

6

7

Switched Outlets LED

When lit, it indicates that the Outlets are powered.

Resettable Circuit Breaker

Provides protection for all Outlets on the product. If no devices are 

powered or LEDs lit, press the circuit breaker to activate power.

8

Always On Outlets

Outlets remain ON all the time.

9

< tv > Outlet

The Outlet includes True RMS Power Measurement outlet for TV.

IMPORTANT

THE TV MUST BE PLUGGED INTO THIS OUTLET

Switched Outlets

Switched off if there is no RF, IR or movement is detected, or if the TV is 

switched off. 

1

2

3

RF/IR + Movement Multi-Sensor 

The ZigBee multi-sensor is connected to the powerstrip via the RJ 11 port 

- marked “sensor”. Mount the ZigBee multi-sensor on the underside of the 

TV, near to the IR receiver on the TV. Typically located next to the TV 

power on/off button. The multi-sensor must be located within line of sight 

of where you normally use your remote controls.

Power Connection

The Product must only be plugged into a grounded receptacle for surge 

protection to operate correctly. All connected devices should be plugged 

directly into the Product. Use of an extension cord, adaptor or other 

powerstrip in conjunction with the Product will void all warranties.

Sensor/RJ11 Port

Plug the RF / IR + Movement multi-sensor into this port.

There will be a soft audible ‘click’ when the connector is inserted correctly.

www.tricklestar.com

Advanced Pow

Advanced 

Pow

Outlet 

7

Product Overview

4 5 6

7

9

8

1

2

3

10

10

Содержание TS1811

Страница 1: ...ommands from the multi sensor to an HDMI port on the TV this feature is known as TAV Link and will result in placement of connected HDMI devices into a power saving state by high level commands KEY FEATURES 7 Outlets 2 Always On Outlets 1 outlet transformer spaced 5 Switched Outlets 1 outlet transformer spaced 15A resettable circuit breaker Auto threshold detection Intelligently adjusts to new equ...

Страница 2: ...ontrols It provides two way high speed communications which allow remote signals to transmit through cabinets obstacles walls and floors CEC Consumer Electronics Control is the control protocol found in HDMI STEP 1 Quickly press the pinhole pairing button located on the back of the multi sensor to trigger the pairing process A blue LED will flash for a period of 15 seconds indicating the multi sen...

Страница 3: ...re the property of their respective owners The information in this document is subject to change without notice TrickleStar assumes no responsibility for any errors that may appear in this document This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference re...

Страница 4: ... TrickleStar LLC 2016 All rights reserved TrickleStar is a registered trademark of TrickleStar Ltd All other trademarks are the property of their respective owners The information in this document is subject to change without notice TrickleStar assumes no responsibility for any errors that may appear in this document For technical support go to www tricklestar com or call 1 888 700 1098 ...

Страница 5: ...ar determines that the damage did not result from the occurrence or that no occurrence in fact took place the repair or replacement of the damaged devices is covered under a manufacturer s warranty TrickleStar determines that the connected devices were not used under normal operating conditions or in accordance with any labels or instructions The Product is not plugged directly into a receptacle T...

Страница 6: ...he occurrence or that no occurrence in fact took place the repair or replacement of the damaged devices is covered under a manufacturer s warranty TrickleStar determines that the connected devices were not used under normal operating conditions or in accordance with any labels or instructions The Product is not plugged directly into a receptacle The Product is daisy chained together in serial fash...

Страница 7: ...R signal from any remote must be received to switch on the switched outlets Alternatively press the button on the multi sensor to switch on switched outlets manually Make sure that the TV is plugged into the outlet with the green TV icon Make sure that the TV peripherals are connected to the green switched outlets except for TV The switched outlets will switch off after the TV has been switched of...

Страница 8: ...nected to the APS and RF or IR signal from any remote must be received to switch on the switched outlets Alternatively press the button on the multi sensor to switch on switched outlets manually Make sure that the TV is plugged into the outlet with the green TV icon Make sure that the TV peripherals are connected to the green switched outlets except for TV The switched outlets will switch off afte...

Страница 9: ...ated there is a grounding problem and you must contact an electrician to properly ground the socket Surge protection will not work with an improperly grounded outlet Surge LED When illuminated it indicates that the surge protection is functioning normally If this LED illuminates red or extinguishes at any time the Product was sacrificed to protect your devices and must be replaced 6 7 Switched Out...

Страница 10: ...t indicates that the Product is correctly grounded If not illuminated there is a grounding problem and you must contact an electrician to properly ground the socket Surge protection will not work with an improperly grounded outlet Surge LED When illuminated it indicates that the surge protection is functioning normally If this LED illuminates red or extinguishes at any time the Product was sacrifi...

Страница 11: ...ch to TV mode Note www tricklestar com Advanced Powerstrip Advanced PowerStrip Outlet 7 Operation Countdown Timer Setting Operation RF Remote Control and Pairing Operation Delete Paired RF Remote ControlAddress Step 1 To configure the countdown timer press and hold the button for 10 seconds until the red LED illuminates Then press Once for 30 minutes Twice for 60 minutes Three times for 120 minute...

Отзывы: