![TriboServ FlexxPump4 BXXX-EXT Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/triboserv/flexxpump4-bxxx-ext/flexxpump4-bxxx-ext_user-manual_1161077017.webp)
Revision: 0
FlexxPump4 B
User Manual
17
EN-
5.3
Commissioning
Mount the FP4 B carefully according to the steps described in chapter 5.2.
Depending on the scope of delivery, you must also carry out the following additional
measures for the first-time commissioning:
1. Mechanical fastening
Fix the FP4 B mechanically. Pay particular attention to the maximum tightening tor-
ques permissible for the M5 female threads!
2. Check the assembly
Make sure that the FP4 B is properly and completely assembled. In particular, the
battery must be inserted and a lubricant cartridge must be fitted.
3. Power on
If you want to put the FP4 B into operation, switch on the FP4 B. Only if you switch
the FP4 B on, it delivers lubricant to the lubrication point according to the settings.
The detailed description for powering on can be found in chapter 6.3.3.
4. Execute FIL function
Execute the FIL function. The detailed description can be found in chapter 6.3.10.
FP4 B performs a certain number of strokes and transports the lubricant from the
cartridge to the outlet.
5. Hydraulic connection
Connect the consumer hydraulically to the FP4 B. If you connect tubes to the FP4 B,
make sure that the tubes and connectors are installed tightly, cleanly and correctly.
Ideally, use tubes prefilled with the appropriate lubricant!
6. Check the settings on FP4 B
Check the factory settings of FP4 B with the required values for the lubrication point
and adjust them if necessary. Changes at the FP4 B must be made in the SET-Menu,
see chapter 6.3.6 or in the PRO-Menu, chapter 6.3.8 or 6.3.9.