![TriboServ FlexxPump4 BXXX-EXT Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/triboserv/flexxpump4-bxxx-ext/flexxpump4-bxxx-ext_user-manual_1161077030.webp)
Revision: 0
FlexxPump4 B
User Manual
30
EN-
6.3.3 Switching on and off
FP4 B is switched off (OFF).
Hold the activation and programming key on the action area. The yellow LED lights
up. Leave the activation and programming key on the action area until ON is displayed
in the LCD. Remove the activation and programming key from the action area as long
as ON is displayed in the LCD. The yellow LED disappears; the LCD flashes together
with the green LED twice.
Ü
If no error is detected during the FP4 B self-check, ON is displayed in the LCD.
The green LED lights up once every 60 seconds, FP4 B is ready for operation and will
dispense lubricant according to the set values.
Insert the activation and programming key into the hole provided on the underside of
the FP4 B.
FP4 B is ON, the green LED flashes every 60 seconds.
Hold the activation and programming key on the action are. The yellow LED lights up.
Leave the activation and programming key on the action area until OFF is displayed
in the LCD. Remove the activation and programming key from the action area as long
as OFF is displayed in the LCD. The yellow LED disappears; the LCD flashes together
with the green LED twice.
Ü
FP4 B is OFF; OFF appears in the LCD. FP4 B stops dispensing lubricant.
Insert the activation and programming key into the hole provided on the underside of
the FP4 B.
FP4 B can be switched off in any state (normal operating state or error) in the man-
ner described here.
Switch the FP4 B on:
Switch the FP4 B off: