![TriboServ FlexxPump4 BXXX-EXT Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/triboserv/flexxpump4-bxxx-ext/flexxpump4-bxxx-ext_user-manual_1161077038.webp)
Revision: 0
FlexxPump4 B
User Manual
38
EN-
No changing of the value of the number of cycles c:
If you do not want to change the value of the number of cycles c, the activation and
programming key must remain removed from the action area immediately after entering
the PRO-Menu.
Ü
The LCD as well as the green LED flashes twice and the number of cycles c is dis
-
played in the LCD.
Insert the activation and programming key into the hole provided on the housing of
the FP4 B.
The PRO-Menu can only be reached from the ON mode (FP4 B switched on).
When you enter the PRO-Menu, you will return to the ON mode.
If you have made changes to the values of the pause time h or the values of the
number of cycles c in the PRO-Menu and the FP4 B is otherwise ready for operation
(battery full and inserted as well as a cartridge fitted), the FP4 B will immediately start
with the calculated waiting time until the next pause.
Observe the back pressure values displayed on the LCD if they are of interest to
you.
During the pause process, the green LED lights up; in addition, the counterpressure
for the stroke is displayed in the LCD.
The parameters that can be set for the pause time h and the number of cycles c and
their respective permissible values are specified as follows:
h :=
Pause time
in hours (h).
The dispensing time can be set between 1 | 2 | 3 | ... | 240 hours.
Values of 1 | ... | 99 are displayed in the LCD with h in front, values of 100 | ... |
240 without h in front.
The time counter integrated in the FP4 B microelectronics starts counting
the pause time h after a successful and completed dispensing cycle.
c :=
Number of cycles
within a dispensing cycle (c).
The number of cycles c can be set between 1 | 2 | 3 | ... | 30 strokes.