MODULE SETTINGS
HMS-1650
-
41
-
Object Instance
Functional Description
Read or Write
ADF - 20
Alarm Relay 3 High Setpoint
Read/Write
ADF - 21
Alarm Relay 3 Low Setpoint
Read/Write
ADF - 22
Alarm Relay 4 High Setpoint
Read/Write
ADF - 23
Alarm Relay 4 Low Setpoint
Read/Write
ADF - 24
AI-2 Low Alarm Setpoint
Read/Write
ADF - 25
AI-2 Low Warning Setpoint
Read/Write
ADF - 26
AI-2 High Warning Setpoint
Read/Write
ADF - 27
AI-2 High Alarm Setpoint
Read/Write
ADF - 28
AI-3 Low Alarm Setpoint
Read/Write
ADF - 29
AI-3 Low Warning Setpoint
Read/Write
ADF - 30
AI-3 High Warning Setpoint
Read/Write
ADF - 31
AI-3 High Alarm Setpoint
Read/Write
ADF - 32
AI-4 Low Alarm Setpoint
Read/Write
ADF - 33
AI-4 Low Warning Setpoint
Read/Write
ADF - 34
AI-4 High Warning Setpoint
Read/Write
ADF - 35
AI-4 High Alarm Setpoint
Read/Write
ADF - 36
TI-1 Low Alarm Setpoint
Read/Write
ADF - 37
TI-1 Low Warning Setpoint
Read/Write
ADF - 38
TI-1 High Warning Setpoint
Read/Write
ADF - 39
TI-1 High Alarm Setpoint
Read/Write
ADF - 40
TI-2 Low Alarm Setpoint
Read/Write
ADF - 41
TI-2 Low Warning Setpoint
Read/Write
ADF - 42
TI-2 High Warning Setpoint
Read/Write
ADF - 43
TI-2 High Alarm Setpoint
Read/Write
ADF - 44
Humidity Network Variable (writable)
Read/Write
ADF - 45
Temperature Network Variable (writable)
Read/Write
ADF - 46
Air Changes Network Variable (writable)
Read/Write
ADF - 47
Differential Pressure Network Variable (writable)
Read/Write
ADF - 48
Air Flow based on Flow Input at AI-1
Read-Only
ADF - 49
Air Flow based on Flow Input at AI-2
Read-Only
ADF - 50
Air Flow based on Flow Input at AI-3 (default: Supply Flow)
Read-Only
ADF - 51
Air Flow based on Flow Input at AI-4 (default: Exhaust Flow)
Read-Only
ADF - 52
Volumetric Offset (Supply Flow – Exhaust Flow)
Read-Only
ADF - 53
Volumetric Offset Setpoint
Read-Write
ADF - 54
AO-1 Override Level
Read-Write
ADF - 55
AO-2 Override Level
Read-Write
ADF - 56
AO-3 Override Level
Read-Write
ADF - 57
AO-4 Override Level
Read-Write
Internal Integer Values
ADI - 1
Fume Hood Operating Mode: 1=occupied, 2=unoccupied, 3=standby
Read/Write
ADI - 7
Secondary Operating Mode: 1=occupied, 2=unoccupied, 3=standby
Read/Write
ADI - 8
AI-2 Alarm Status: 1=normal, 2=warning, 3=alarm
Read-Only
ADI - 9
AI-3 Alarm Status: 1=normal, 2=warning, 3=alarm
Read-Only
ADI - 10
AI-4 Alarm Status: 1=normal, 2=warning, 3=alarm
Read-Only
ADI - 11
TI-1 Alarm Status: 1=normal, 2=warning, 3=alarm
Read-Only
ADI - 12
TI-2 Alarm Status: 1=normal, 2=warning, 3=alarm
Read-Only
Metasys® N2 Objects