Baffle Configurations ( 15/20 kW & 20/26kW )
Main Baffles
Important
: As shown above, the ‘skirt’ (1) on the underside of each baffle must be hooked over the rear of
the lug (2) on the baffle immediately below. The use of a tool may be required to lift the third baffle (3) from
the combustion chamber. Insert a screwdriver or similar into the lifting hole in the centre of the baffle and
raise above the lip of the baffle access channel. Failure to ensure the correct placement of the baffles will
result in incorrect combustion and may invalidate the appliance warranty.