16
4.
Replace flue-baffles in the correct arrangement
(See Fig. 9 for order of assembly). Refit the flue-
cover and fully tighten wing-nuts to make a gas tight
seal.
5.
Refit burner to boiler, connect flexible air hose
and plug-in burner lead.
6.
Turn on oil supply, switch on electricity and burner
should fire.
7.
Finally check the combustion readings with those
given under ‘Burner Settings’ and make any air or oil
pressure adjustments necessary.
Servicing the Boiler
(Burner removed)
1.
Remove flue-cover and lift out flue-baffles
(See Fig. 9).
2.
Brush all deposits from flue-baffles and internal
surfaces of the boiler.
3.
Remove flue deposits from the combustion chamber
floor using a vacuum cleaner.
PART NO.208838
3-OFF
PART NO.208834
1-OFF
PART NO.208865
2-OFF
PART NO.208871
6-OFF
EuroStar 50/90
BAFFLE ARRANGEMENT
FRONT ACCESS
EuroStar 115
BAFFLE ARRANGEMENT
TOP ACCESS
FIG. 9