FIG. 4 SINGLE PIPE OIL SUPPLY INSTALLATION
FIG. 5 TWO PIPE OIL SUPPLY INSTALLATION
11
HEAD ‘H’ METRES.
.0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
PIPE 6mm ID
10
21
31
41
52
62
73
83
PIPE 8mm ID
33
66
98
100
100
100
100
100
MAXIMUM OIL SUPPLY LINE LENGTH ‘L’
MAXIMUM
LENGTH
(METRES)
LIFT ‘L’ METRES.
.0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
PIPE 6mm ID
48
42
36
30
24
18
11
5
PIPE 8mm ID
100
100
100
94
75
55
36
16
PIPE 10MM ID
100
100
100
100
100
100
88
40
MAXIMUM OIL SUPPLY LINE LENGTH ‘L’
MAXIMUM
LENGTH
(METRES)
TRIANCO
EUROSTAR BOILER
FIRE VALVE SENSOR
FIRE VALVE SENSOR
BURNER
BURNER
SHUT OFF VALVE
SHUT OFF VALVE
H
NONE RETURN VALVE
FITTED IN VERTICAL
PIPE RUN
50mm(2'') DIA
AIR VENT
50mm(2'') DIA
AIR VENT
SAW CUT PIPE (INSIDE TANK)
TO PREVENT SYPHON
LEVEL GAUGE
LEVEL GAUGE
25mm (1'')
APPROX FALL
ISOLATING VALVE
ISOLATING
VALVE
LEVEL GAUGE
VALVE
LEVEL GAUGE
VALVE
DAMP
PROOF
MATERIAL
MIN HEAD
0.5m(H)
TERMINAL
TERMINAL
GUARD
GUARD
OIL LEVEL LINE
FILTER
FILTER
REMOTE OPERATED FIRE VALVE
REMOTE OPERATED FIRE VALVE
2'' BSP MALE
HOSE CONNECTION
WITH CAP
2'' BSP MALE
HOSE CONNECTION
WITH CAP
STEEL
OIL STORAGE TANK
STEEL
OIL STORAGE TANK
25mm (1'')
APPROX
FALL
DRAIN VALVE
DRAIN VALVE
100mm
TRIANCO
EUROSTAR BOILER