background image

11 

 

 

PARTS LIST:                        TSGCB-18i & TSGCRB-18i 

Item  P/N 

Description 

Quan 

Item 

P/N 

Description 

Quan 

218207-55 

Weldment, 18" Bullnose 

35 

218212-16 

Radiant Med Duty - H 

218215-11 

Body, 18" Firebox GGM 

36 

43813149 

Label, Warning Hot Surface (French) 

8431300 

1/4-20 Flanged Hex Locknut 

37 

8706300 

Knob, Metal Cook line .375 D Shaft 

21813085 

Spacer 

38 

8633700 

Leg, HD 2” Diameter W/Foot Flange. 

22011191 

Baffle, 18" Front Heat 

39 

2425400 

Pan, Grease Cook Line 18” 

Short Draw

 

8417100 

Nut, Hex, KEPS 10-32 

40 

21813029 

Grate Support 

22030005 

Support, Leg 18", i-Line 

41 

3103800 

Grill Grate 

218215-13 

Bracket, Manifold 

GCRB/GCB/GGM-18

 

42 

2067300 

Regulator, Convertible 3/4 ½ PSIG 

8153100 

#8-32 X 3/8 Type T 

11 

43 

8861000 

Label, Spec 

10 

22011198 

Manifold, 18" 

GCBi/GCRBi/GGMi

 

44 

8809920 

Decal, Improper Installation 

11 

2068200 

Valve, Gas, On-Off 

45 

8832600 

Label, Service Hotline 

12 

2066828 

Orifice #28 

46 

8837130 

Decal, Operating Instruction 

13 

2066841 

Hood, Orifice #41 

47 

8825300 

Decal, Leg 

14 

2092517 

Plug, 1/8 NPTM 

48 

8822325 

Decal, UL Sanitation, NSF Std. 4 

15 

2065643 

Valve, 90° Pilot 1/8" NPT X 3/16 

49 

8837112 

Label, Orifice Size 

16 

218207-28 

Tube, Pilot 

50 

8837190 

Tag, Orifice Location 

17 

218207-29 

Bracket, Pilot 

GCRB/GCB/GGM-18

 

51 

43813103 

Label, Warning, Hot Surface 

18 

2066154 

Pilot, Top 

52* 

2300100 

Bags, Poly 36 x 27 x 44 

19 

218207-16 

Side, Grease Chute 

53* 

2065852 

Logo, Tristar Casted  

20 

22011254 

Side Panel, LH & RH, i-Line 

54* 

2901251 

Carton, RSC 

28.25 X 20.62 X 17, 275lbs

 

21 

8170700 

Screw, 10-32x1/2, Type AB 

12 

55* 

29012-35 

Pad Accessory 

22 

30047501 

Guide, Grease Slide 

56* 

2901255 

Post Corner 

23 

218207-57 

Panel, Back 

57* 

8837201 

Bag, Cloth, 4" x 6" w/Drawstring 

24 

218207-17 

Support, Burner 

58* 

8838700 

Manual, GCB-H/GCRB-H 

Champion II

 

25 

81546-00 

#8 X 3/8 

59* 

2900851 

Skid, 21.75 X 29.5 

26 

218130-75 

Burner "S? 

60* 

2901240 

Pad 

27 

31007-12 

U-Nut C7685 10A Tinnerman 

61* 

8837400 

Box Label, Tristar 

28 

22011195 

Baffle, Front Panel 18”, i-Line 

62* 

3100001 

Lava Rocks, 8lb Bag 

29 

22011196 

Panel, Control 18” 

GCRBi/GCBi Safety 

/IGN

 

63* 

2901231 

Carton, RSC 

23-7/16 X 16-1/16 X 4 275DW

 

 

22011193 

Panel, Control 18” 

GCRBi/GCBi/GGMi

 

 

64* 

2300000 

29 x 19 x 44 Poly 

 

30 

81973-00 

T/S #10 X 1/2 TPB Tr Hd 

65* 

8899300 

List Of Service Agencies 

33 

218207-53 

Support, 18" Rock Grate, Rear 

66 

3102205 

Grate, Rock 

34 

218207-22 

Support, 18" Rock Grate, Front 

67 

218207-26 

Guard, Burner 

 

 

 

 

 

 

* = Not Shown 

Содержание TSGCB-18i

Страница 1: ... WARNING Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintaining or servicing this equipment WARNING Instructions must be posted in a prominent location All safety precautions must be taken in the event the user smells gas Safety information can be obtained from your...

Страница 2: ...s supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa The appliance must be isolated from the gas supply piping system by closing it s individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 45 kPa WARNING A factory authorized agent should handle all maintenanc...

Страница 3: ...l result in serious injury or death WARNING This symbol refers to a potential hazard or unsafe practice which could result in serious injury or death CAUTION This symbol refers to a potential hazard or unsafe practice which may result in minor or moderate injury or product or property damage NOTICE This symbol refers to information that needs special attention or must be fully understood even thou...

Страница 4: ... gas line is disconnected Unit must have adequate clearances for servicing Sides 0 Rear 0 Floor 4 European Community Installation Instructions THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON IN THE UK CORGI REGISTERED INSTALLERS INCLUDING THE REGIONS OF BRITISH GAS UNDERTAKE TO WORK TO SAFE AND SATISFACTORY STANDARDS THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE GAS SAFETY INSTALLATI...

Страница 5: ...emove the knobs and front panel 2 Remove the orifice fittings from the valve Change the orifices to the size recommended for propane L P 3 Replace the orifice fittings into the valve 4 Remove cap invert the insert and replace cap NOTE Marking on insert 5 Continue with the installation LIGHTING INSTRUCTIONS GCB and GCRB Broilers are furnished with either a pilot safety valve or a standing pilot not...

Страница 6: ...Turn off the manual shut off valve and wait 5 minutes to clear the gas 2 Turn all knobs to the OFF position 3 Turn the manual shut off valve on 4 Hold an ignition source match at the pilot When the flame is established remove the ignition source 5 Turn the burner knobs to HI If the burner does not ignite promptly open the pilot valve more If the pilot flame appears larger than necessary turn it do...

Страница 7: ...currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a subnormal atmospheric pressure will occur which will effect operation and cause undesirable working conditions A properly designed and installed hood will act as the heart of the ventilating system for the room or area...

Страница 8: ...ricting the airflow by covering the grid grates may cause them to warp It will also cause damage to the valves the knobs and the front panel decal C Place grates on broiler with grid bars horizontal facing down D Turn control knobs to HI for approximately 45minutes E Turn off the broiler and allow it to cool for 20Minutes F Clean top and bottom surfaces of grate with a wire brush to remove animal ...

Страница 9: ...djusted by the installer unless the installer is an authorized service agent TROUBLE SHOOTING GUIDE PROBLEM POSSIBLE CAUSE Heat does not come on when valve is turned on Pilot burner not lit Gas valve is bad Pilot burner will not light Obstructed pilot orifice Pilot gas turned off at automatic pilot Automatic pilot valve is bad Pilot burner will not stay lit Thermocouple is bad Thermocouple is not ...

Страница 10: ...KS WITH AIR SPACES BETWEEN THE ROCKS DO NOT OVER LOAD ROCK GRATES Please Use The Following Amount of Lava Rock Per Model GCRB 18 Approximately 3 LBS GCRB 24 Approximately 4 LBS GCRB 36 Approximately 7 LBS GCRB 48 Approximately 9 LBS Notes ...

Страница 11: ...X 3 16 1 49 8837112 Label Orifice Size 1 16 218207 28 Tube Pilot 1 50 8837190 Tag Orifice Location 1 17 218207 29 Bracket Pilot GCRB GCB GGM 18 1 51 43813103 Label Warning Hot Surface 1 18 2066154 Pilot Top 1 52 2300100 Bags Poly 36 x 27 x 44 1 19 218207 16 Side Grease Chute 2 53 2065852 Logo Tristar Casted 1 20 22011254 Side Panel LH RH i Line 2 54 2901251 Carton RSC 28 25 X 20 62 X 17 275lbs 1 2...

Страница 12: ...12 EXPLODED VIEW TSGCB 18i TSGCRB 18i ...

Страница 13: ...4 Side Panel LH RH i Line 2 53 2901255 Post Corner 4 18 30047501 Guide Grease Slide 2 54 2901252 Carton HSC 28 1 4 X 26 5 8 X 17 275 Lbs 1 19 218208 25 Bracket Pilot 1 55 2901229 Pad 21 13 16 X 23 3 16 200 Lbs 1 20 218212 16 Radiant Medium Duty H 4 56 29012 28 Cap FTD 24 25 X 23 25 X 4 275 Lbs 1 21 2092800 Pilot Broiler 1 57 29012 27 Cap FTD 23 43 X 22 06 X 4 275 Lbs 1 22 22011255 Baffle Front Pan...

Страница 14: ...14 EXPLODED VIEW TSGCB 24i TSGCRB 24i ...

Страница 15: ...PTM 1 52 8837130 Decal Operating Instruction 1 17 218208 25 Bracket Pilot 2 53 2065852 Logo Tristar Casted 1 18 2092800 Pilot Broiler 2 54 8837190 Tag Orifice Location 1 19 8163100 M S Pan Hd Ph 10 32 X 1 4 4 55 43813103 Label Warning Hot Surface 1 20 2092903 Pilot Natural 6 W C 2 56 8837400 Box Label 1 21 2068001 Pilot Valve 2 57 8838700 Manual GCB H GCRB H Champion II 1 22 21820727 Tube Pilot Su...

Страница 16: ...16 EXPLODED VIEW TSGCB 36i TSGCRB 36i ...

Страница 17: ...1198 Manifold 18 GCBi GCRBi GGMi 4 54 8822325 Decal UL Sanitation NSF Std 4 1 19 22011254 Side Panel LH RH i Line 2 55 29012 27 Cap FTD 23 43 X 22 06 X 4 275 Lbs 2 20 30047501 Guide Grease Slide 4 56 29012 28 Cap FTD 24 25 X 23 25 X 4 275 Lbs 2 21 218212 16 Radiant Med Duty H 8 57 29012 43 Pad 27 X 52 5 200lbs 1 22 218210 51 Body 48 Firebox GGM 1 58 2901229 Pad 21 13 16 X 23 3 16 200lbs 2 23 81973...

Страница 18: ...18 EXPLODED VIEW TSGCB 48i TSGCRB 48i ...

Страница 19: ...TAR shall bear the normal labor charges for repair of replacement to the extent that such repair or replacement is performed within 35 miles of the office of an authorized service agency within the continental United States and during regular straight time hours Travel outside of the 35 miles and any work performed at overtime or weekend rates would be the responsibility of the owner user Defectiv...