GENERAL INSTALLATION INSTRUCTIONS 

Ensure gas supply and gas type, as shown on unit nameplate, agree. 

Unit  installation  must  conform  with  the  National  Fuel  Gas  Code,  ANSI  Z223.1/NFPA  54,  the  National  Gas 
Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and in accordance 
with local codes. 

Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the unit 
by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if necessary 
to move unit.  

Pipe threading compound must be resistant to the action of liquefied petroleum gases.  

Caution:

 DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and water 

solution before operating unit. 

THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY. 

Noncombustible clearances: 

0" sides (0 mm)               0" rear (0 mm)               4" floor (102mm) 

Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the 
flue.  

Adequate clearance for air openings into the combustion chamber is required. Do not place objects between the 
bottom of the unit and the counter top.  

There  must  be  adequate  clearance  for  removal  of  the  front  panel.  All  major  parts  except  the  burners  are 
removable thru the front if the gas line is disconnected. 

Unit must have adequate clearances for servicing. (Sides = 0", Rear = 0", Floor = 4"). 

European Community Installation Instructions: 

"THIS  APPLIANCE  MUST  BE  FITTED  BY  A  COMPETENT  PERSON.  IN  THE  UK,  CORGI  REGISTERED 
INSTALLERS  (INCLUDING  THE  REGIONS  OF  BRITISH  GAS)  UNDERTAKE  TO  WORK  TO  SAFE  AND 
SATISFACTORY STANDARDS. THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE GAS 
SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELEVANT BUILDING REGULATIONS / IEE. 
REGULATIONS.  DETAILED  RECOMMENDATIONS  ARE  CONTAINED  IN  THE  FOLLOWING  BRITISH 
STANDARD CODES OF PRACTICE -BS 6172, BS 5440 PART 2, BS 6891" 

"THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE"  

"MUST BE INSTALLED IN A WELL VENTILATED AREA. Ventilation requirements ie. B.S. 5440." 

SPECIFICATIONS AND DIMENSIONS 

 

MODEL 

IN. (MM) 

IN. (MM) 

IN. (MM) 

IN. (MM) 

# OF 

BURNERS 

BTU/kW PER 

BURNER 

NATURAL GAS 

TOTAL 

BTU/kW 

HOUR 

W.C. 

IN.('Mbar') 

GCB-18i 

18 (457) 

24.1 (639)  15.6 (396) 

9.0 (229) 

60,000/17.5 

60,000/17.5 

6/10(15/25) 

GCB-24i 

24 (610) 

24.1 (639)  15.6 (396) 

8.6 (219) 

40,000/11.7 

80,000/23.5 

6/10(15/25) 

GCB-36i 

36 (914) 

24.1 (639)  15.6 (396) 

9.6 (243) 

40,000/11.7 

120,000/35 

6/10(15/25) 

GCB-48i 

48 (1219) 

24.1 (639)  15.6 (396) 

10.6 (269) 

40,000/11.7 

160,000/46.8 

6/10(15/25) 

GCRB-18i 

18 (457) 

24.1 (639)  15.6 (396) 

9.0 (229) 

60,000/17.5 

60,000/17.5 

6/10(15/25) 

GCRB-24i 

24 (610) 

24.1 (639)  15.6 (396) 

8.6 (219) 

40,000/11.7 

80,000/23.5 

6/10(15/25) 

GCRB-36i 

36 (914) 

24.1 (639)  15.6 (396) 

9.6 (243) 

40,000/11.7 

120,000/35 

6/10(15/25) 

GCRB-48i 

48 (1219) 

24.1 (639)  15.6 (396) 

10.6 (269) 

40,000/11.7 

160,000/46.8 

6/10(15/25) 

 

Содержание TSGCB-18i

Страница 1: ... WARNING Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintaining or servicing this equipment WARNING Instructions must be posted in a prominent location All safety precautions must be taken in the event the user smells gas Safety information can be obtained from your...

Страница 2: ...s supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa The appliance must be isolated from the gas supply piping system by closing it s individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 45 kPa WARNING A factory authorized agent should handle all maintenanc...

Страница 3: ...l result in serious injury or death WARNING This symbol refers to a potential hazard or unsafe practice which could result in serious injury or death CAUTION This symbol refers to a potential hazard or unsafe practice which may result in minor or moderate injury or product or property damage NOTICE This symbol refers to information that needs special attention or must be fully understood even thou...

Страница 4: ... gas line is disconnected Unit must have adequate clearances for servicing Sides 0 Rear 0 Floor 4 European Community Installation Instructions THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON IN THE UK CORGI REGISTERED INSTALLERS INCLUDING THE REGIONS OF BRITISH GAS UNDERTAKE TO WORK TO SAFE AND SATISFACTORY STANDARDS THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE GAS SAFETY INSTALLATI...

Страница 5: ...emove the knobs and front panel 2 Remove the orifice fittings from the valve Change the orifices to the size recommended for propane L P 3 Replace the orifice fittings into the valve 4 Remove cap invert the insert and replace cap NOTE Marking on insert 5 Continue with the installation LIGHTING INSTRUCTIONS GCB and GCRB Broilers are furnished with either a pilot safety valve or a standing pilot not...

Страница 6: ...Turn off the manual shut off valve and wait 5 minutes to clear the gas 2 Turn all knobs to the OFF position 3 Turn the manual shut off valve on 4 Hold an ignition source match at the pilot When the flame is established remove the ignition source 5 Turn the burner knobs to HI If the burner does not ignite promptly open the pilot valve more If the pilot flame appears larger than necessary turn it do...

Страница 7: ...currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a subnormal atmospheric pressure will occur which will effect operation and cause undesirable working conditions A properly designed and installed hood will act as the heart of the ventilating system for the room or area...

Страница 8: ...ricting the airflow by covering the grid grates may cause them to warp It will also cause damage to the valves the knobs and the front panel decal C Place grates on broiler with grid bars horizontal facing down D Turn control knobs to HI for approximately 45minutes E Turn off the broiler and allow it to cool for 20Minutes F Clean top and bottom surfaces of grate with a wire brush to remove animal ...

Страница 9: ...djusted by the installer unless the installer is an authorized service agent TROUBLE SHOOTING GUIDE PROBLEM POSSIBLE CAUSE Heat does not come on when valve is turned on Pilot burner not lit Gas valve is bad Pilot burner will not light Obstructed pilot orifice Pilot gas turned off at automatic pilot Automatic pilot valve is bad Pilot burner will not stay lit Thermocouple is bad Thermocouple is not ...

Страница 10: ...KS WITH AIR SPACES BETWEEN THE ROCKS DO NOT OVER LOAD ROCK GRATES Please Use The Following Amount of Lava Rock Per Model GCRB 18 Approximately 3 LBS GCRB 24 Approximately 4 LBS GCRB 36 Approximately 7 LBS GCRB 48 Approximately 9 LBS Notes ...

Страница 11: ...X 3 16 1 49 8837112 Label Orifice Size 1 16 218207 28 Tube Pilot 1 50 8837190 Tag Orifice Location 1 17 218207 29 Bracket Pilot GCRB GCB GGM 18 1 51 43813103 Label Warning Hot Surface 1 18 2066154 Pilot Top 1 52 2300100 Bags Poly 36 x 27 x 44 1 19 218207 16 Side Grease Chute 2 53 2065852 Logo Tristar Casted 1 20 22011254 Side Panel LH RH i Line 2 54 2901251 Carton RSC 28 25 X 20 62 X 17 275lbs 1 2...

Страница 12: ...12 EXPLODED VIEW TSGCB 18i TSGCRB 18i ...

Страница 13: ...4 Side Panel LH RH i Line 2 53 2901255 Post Corner 4 18 30047501 Guide Grease Slide 2 54 2901252 Carton HSC 28 1 4 X 26 5 8 X 17 275 Lbs 1 19 218208 25 Bracket Pilot 1 55 2901229 Pad 21 13 16 X 23 3 16 200 Lbs 1 20 218212 16 Radiant Medium Duty H 4 56 29012 28 Cap FTD 24 25 X 23 25 X 4 275 Lbs 1 21 2092800 Pilot Broiler 1 57 29012 27 Cap FTD 23 43 X 22 06 X 4 275 Lbs 1 22 22011255 Baffle Front Pan...

Страница 14: ...14 EXPLODED VIEW TSGCB 24i TSGCRB 24i ...

Страница 15: ...PTM 1 52 8837130 Decal Operating Instruction 1 17 218208 25 Bracket Pilot 2 53 2065852 Logo Tristar Casted 1 18 2092800 Pilot Broiler 2 54 8837190 Tag Orifice Location 1 19 8163100 M S Pan Hd Ph 10 32 X 1 4 4 55 43813103 Label Warning Hot Surface 1 20 2092903 Pilot Natural 6 W C 2 56 8837400 Box Label 1 21 2068001 Pilot Valve 2 57 8838700 Manual GCB H GCRB H Champion II 1 22 21820727 Tube Pilot Su...

Страница 16: ...16 EXPLODED VIEW TSGCB 36i TSGCRB 36i ...

Страница 17: ...1198 Manifold 18 GCBi GCRBi GGMi 4 54 8822325 Decal UL Sanitation NSF Std 4 1 19 22011254 Side Panel LH RH i Line 2 55 29012 27 Cap FTD 23 43 X 22 06 X 4 275 Lbs 2 20 30047501 Guide Grease Slide 4 56 29012 28 Cap FTD 24 25 X 23 25 X 4 275 Lbs 2 21 218212 16 Radiant Med Duty H 8 57 29012 43 Pad 27 X 52 5 200lbs 1 22 218210 51 Body 48 Firebox GGM 1 58 2901229 Pad 21 13 16 X 23 3 16 200lbs 2 23 81973...

Страница 18: ...18 EXPLODED VIEW TSGCB 48i TSGCRB 48i ...

Страница 19: ...TAR shall bear the normal labor charges for repair of replacement to the extent that such repair or replacement is performed within 35 miles of the office of an authorized service agency within the continental United States and during regular straight time hours Travel outside of the 35 miles and any work performed at overtime or weekend rates would be the responsibility of the owner user Defectiv...

Отзывы: