Page 32
Step 16.
Rotate the indenter plate, insert the cam arm into the arbor shaft and
set the plate onto the housing.
NOTE: The arbor shaft can be rotated slightly to facilitate cam arm insertion.
Step 17.
Proceed to Paragraph 6-9, Step 4.
The adjustment of indenters should be performed whenever existing indenters are
slightly worn and "G" dimension is out-of-tolerance, when Crimp Verification (Section
3) dictate adjustment is necessary, and when new indenters have been installed
(Paragraph 6-8).
Perform the following steps to adjust indenters:
Step 1.
Open the sleeve valve.
Step 2.
Disconnect the air supply from the sleeve valve.
Step 3.
Remove the crimp cylinder arbor cover plate and the funnel cover
plate.
Step 4.
Refer to Table 6-1. If the TAC Crimper has an operator-adjustable "G"
dimension control, set the control to setting 6 (the largest wire gauge).
If the setting is not adjustable, perform the GO/NO-GO tests and adjust
I
NDENTER
ADJUSTMENT
Contact
Gauge
Setting
Wire
Gauge
Go
No-Go
22
1
26
.016
.021
22
2
24
.019
.024
22
3
22
.022
.027
20
4
24
.025
.030
20
5
22
.029
.034
20
6
20
.033
.038
16
1 or 4
20
.029
.034
16
2 or 5
18
.033
.038
16
3 or 6
16
.037
.042
Содержание TAC-10X
Страница 5: ...Page 5 Figure 1 1 TAC 10X Front View ...
Страница 7: ...Page 7 Figure 1 2 Wire Insertion Through Funnel ...
Страница 10: ...Page 10 Figure 2 1 Pneumatic Hook Ups Air Off Air On ...
Страница 12: ...Page 12 Figure 2 3 Shoulder less Track Assembly Track Assembly Figure 2 4 Shoulder less Track Assembly ...
Страница 16: ...Page 16 Crimp Inspection Points Improper Crimps Figure 3 3 Crimped Samples ...
Страница 24: ...Page 24 Figure 6 1 TAC 10X Pneumatic Control Panel ...
Страница 25: ...Page 25 Figure 6 2 TAC 10X Components Right View ...
Страница 26: ...Page 26 PLC Controller Switching Power Supply Figure 6 3 TAC 10X Components Left View ...
Страница 30: ...Page 30 ...
Страница 31: ...Page 31 Carefully Remove Hose Clamp ...
Страница 34: ...Page 34 ...
Страница 38: ...Page 38 Figure 7 3 TAC 10X Pneumatic Diagram ...