Page 14
Step 5.
Remove the crimp cylinder arbor cover plate and the funnel cover plate.
Step 6.
Refer to Table 3-1. If the TAC has a operator-adjustable "G" dimension
control, perform Steps 6 through 9 for the fixed "G" dimension.
Contact
Gauge
Setting
Wire
Gauge
Go
No-Go
22
1
26
.016
.021
22
2
24
.019
.024
22
3
22
.022
.027
20
4
24
.025
.030
20
5
22
.029
.034
20
6
20
.033
.038
16
1 or 4
20
.029
.034
16
2 or 5
18
.033
.038
16
3 or 6
16
.037
.042
TABLE 3-1. GO NO-GO DIMENSIONS
M22520/7-01
Step 7.
Using only hand pressure, extend the arbor as far to the right as it will
go. (Refer to Figure 3-2).
Step 8.
Using GO and NO-GO gauges, open the funnel and insert gauges into
the indenters to determine the "G" dimension.
Figure 3-2: Crimp Cylinder Arbor, Closed
Содержание TAC-10X
Страница 5: ...Page 5 Figure 1 1 TAC 10X Front View ...
Страница 7: ...Page 7 Figure 1 2 Wire Insertion Through Funnel ...
Страница 10: ...Page 10 Figure 2 1 Pneumatic Hook Ups Air Off Air On ...
Страница 12: ...Page 12 Figure 2 3 Shoulder less Track Assembly Track Assembly Figure 2 4 Shoulder less Track Assembly ...
Страница 16: ...Page 16 Crimp Inspection Points Improper Crimps Figure 3 3 Crimped Samples ...
Страница 24: ...Page 24 Figure 6 1 TAC 10X Pneumatic Control Panel ...
Страница 25: ...Page 25 Figure 6 2 TAC 10X Components Right View ...
Страница 26: ...Page 26 PLC Controller Switching Power Supply Figure 6 3 TAC 10X Components Left View ...
Страница 30: ...Page 30 ...
Страница 31: ...Page 31 Carefully Remove Hose Clamp ...
Страница 34: ...Page 34 ...
Страница 38: ...Page 38 Figure 7 3 TAC 10X Pneumatic Diagram ...