44
No part of this document may be reproduced, stored in retrieval system or transmitted by
any means, electronic, mechanical, photocopying, recording or otherwise, without written
permission from Tri-Star Technologies.
•
One Section Mode
enables the import of the total wire length. This option requires one
length to have a specific column and other two to the have default values. For example,
Length 2 come from Column 5 and is 50. The DefaultLength 1 is 5 and the
DefaultLength 3 is 10. After importing the file the Length 2 will be 35.
Fig.9.12. Import Configuration and Edit Mode
Modify the configuration in the following order:
1.
Click anywhere in the grid to select the section that has to be changed.
2.
Click
Edit
button to enter
Edit Mode
.
Column Number
dropdown list will appear.
Select a column number from the dropdown list or select
Default Value
. Set the Default
Value in the text box to the right default value.
3.
Click
Save
to save changes to the section or
Cancel
to return to previous values.
4.
Click
New
to enter Edit Mode for a new section to the Import Configuration. Enter
column numbers or default values for Message, Length and Gap and click
Save
to add
the new section to the Import Configuration. Click
Delete
to delete section for the Import
Configuration. Click
Close
to close the Import Configuration window and save all
values.
If the text file does not have a parameter such as message, gap, length or leading space
select default value in the appropriate dropdown list. Then enter default value in corresponding
textbox.