40
No part of this document may be reproduced, stored in retrieval system or transmitted by
any means, electronic, mechanical, photocopying, recording or otherwise, without written
permission from Tri-Star Technologies.
Enable Z-Axis
is for marking within a 3D object.
Laser Mode
specifies Scanboard signals that are used for laser controls.
Laser Period
determines remote Q-SW triggering frequency. Frequency is factory set up for
optimum laser performance. Altering the frequency may change laser performance and marking
pattern.
Pulse Width 1
determines the duty cycle of the triggering signal. Pulse width of 16ms for the
laser period of 33ms corresponds to the 50% duty cycle.
Pulse Width 2 is
only used for CO2 lasers.
Click the
Save
button to reinitialize the Scanner.
Click the
Cancel
button to close the window without saving. Detailed description of the