7. Maintenance and Troubleshooting
M100LFG-TT-A requires minimum maintenance for continual trouble-free operation.
It is recommended to
•
Keep the wire marker in dry and clean environment.
•
Keep the cabinet clean.
•
Clean the pulling mechanism from wire debris, residue and dust on a daily basis.
•
Clean the wire guides weakly
•
Inspect the belts for wear and tear, clean from dust, replace if necessary
•
Inspect compressed air filters monthly, drain excessive moisture.
•
Inspect I/O cables and power cords for damage and loose fit.
Basic malfunctions are listed in the following table:
Problems
Causes
/
Solutions
Power-ON light is not
illuminated.
Line cord is not connected. Main power switch on the back of the cabinet
is not on.
•
Offset Alignment problem/ see above
•
Laser does not switch into the power mode/ Check Scanalone
Q-SW connection to the back of Laser Power Supply.
•
Power supply malfunction/ Consult factory
Marking is not legible (low
contrast)
•
Wire is not laser markable.
•
Laser power is below normal
Lower the objective position (Chapter 10.4).
Reduce the line spacing and marking speed (chapter 10.2&3)
Ship the laser back to the factory for the repair
Motors are not moving
Consult factory