![Tri-Clover Tri-Flo CL Series Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/tri-clover/tri-flo-cl-series/tri-flo-cl-series_service-and-installation-manual_1159609020.webp)
- 20 -
MAINTENANCE
9.
Install the stainless steel drive collar (18) with the spring (16) and rotating seal (15) onto the
stub shaft.
Ensure the drive collar pin enters the notch on the rotating seal cup when the spring
is compressed.
10. Slide the seal installation tool (50) over the stub shaft, tapered end out, until it abuts with
the shoulder of the stub shaft. (This tool can also be used for disassembly to protect the
seals.)
11. Check to make certain lip seal is still seated correctly. Slide casing (1) with the assembled
seals over installation tool and onto the stub shaft.
12. Remove seal installation tool (50).
13. Install casing (1) to pump adapter with nuts (13) and washers (14). Tighten nuts and
washers.
14. Screw impeller (2) to stub shaft.
15. Install o-ring (5) in impeller.
16. Install impeller screw (4) on stub shaft. Torque impeller screw to 180 lb-in or 15 lb-ft (21
Nm). For the CL4311 and the CL6410, torque the impeller screw to 30 lb-ft (41 Nm).
17. Install flushing pipes (24) to stuffing box.