![Tri-Clover Tri-Flo CL Series Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/tri-clover/tri-flo-cl-series/tri-flo-cl-series_service-and-installation-manual_1159609012.webp)
- 12 -
MAINTENANCE
ROTATING SEALS DISASSEMBLY
1.
Remove and disassemble seals according to the appropriate configuration shown and described.
Type DG - External Balanced Seal
2.
Remove the rotating seal (15), o-ring (5), spring (16) and drive collar (17) from stub shaft.
CL4311 and CL6410: Remove 15, 5, 16, and 18 from the stub shaft. Remove pin (19) as
needed.
Type FG - Water Cooled Single Seal
3.
Remove rotating seal (15), o-ring (5), spring (16), and stainless steel drive collar (18) from
stub shaft.
4.
Remove pin (19) from stainless steel drive collar as required.
5.
Remove o-ring (5) from stainless steel drive collar.
6.
Remove o-ring (20) from stuffing box (22).
7.
Remove single flush lip seal (21) from stuffing box (22).