6
INSTALLATION
INSTALLATION GUIDELINES
UNPACKING EQUIPMENT
When unpacking your equipment, inspect all of the contents for damage that may have occurred
during shipping. Report any damage to the carrier.
LOCATION AND INSTALLATION
The Tri-Blender unit should be located within 3 feet of the liquid source for best performance and in a
position where the supply piping can be short and direct with a minimum number of elbows and
fittings. The liquid to the blender must be supplied by an auxiliary source. It should also be readily
accessible for cleaning and inspection.
The Tri-Blender unit is ready to install as received from the factory. A minimum space of 32" x 47"
(81cm x 119cm) is required. Install the adjustable legs in the base of the unit and position the blender
in the area it will be used. Turn the adjusting leg with a wrench and individually adjust the legs until
the unit is level.
Attach the supply and discharge piping. Be sure that both the inlet and outlet tubes are correctly
positioned and that supply and discharge piping are properly supported to avoid strain on the blender
casing.
The tube OD of the inlet and outlet connections of the blender casing are:
Liquid Inlet
Liquid Outlet
Powder Inlet
1½" (38.1mm)
2" (50.8mm)
3" (76.2mm)
IMPORTANT:
If your blender is equipped with the electrically controlled Butterfly valve,
be sure the valve is wired to an auxiliary 110V power source. The axillary
wiring will let the Butterfly operate independently from the blender motor
and will allow the valve to be closed if the drive motor stops running. If
the auxiliary 110V power source also fails, the Butterfly valve is equipped
with a manual override to close (or open) the valve by applying a suitable
size wrench to the flats on the coupling adapter.