E
xclusive
C
ertification
C
orp
.
Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
61 of 61
EMC
Test Report: CE03111004-A
27. Conducted Disturbances Induced by
Radio-Frequency Field Immunity Test (CS)
Final Test Result
:
PASS
Pass performance Criteria
:
CT/CR
Required performance criteria :
CT/CR
Basic Standard
:
EN 61000-4-6 :1996/A1:2000
Product Standard
EN 301 489-17
Level
:
2
Test Voltage
3 V rms ( Modulated, 1KHz, 80%, AM )
Frequency Range
0.15 MHz to 80 MHz
Dwell time
2.9 seconds
Frequency step size
1 %
Coupling mode
CDN-M2 for AC power ports, Clamp for Signal Ports
Temperature :
25
°
C
Relative Humidity
:
50 %
Test Date
:
Nov. 28, 2003
Observation :
Normal
27.1.
TEST LEVEL
Frequency Range (MHz)
Tested Line
Test Result
0.15~80 Power
Line
N
0.15~80 LAN
Line
N
Note: “N” means the EUT function was correct during the test.
27.2.
OPERATING CONDITION
Full system