E
xclusive
C
ertification
C
orp
.
Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
59 of 59
EMC
Test Report: CE03111004-A
26. Surge Immunity Test
FINAL TEST RESULT
:
PASS
Pass performance Criteria
:
CT/CR
Required performance criteria :
TT/TR
Basic Standard
:
EN 61000-4-5 :1995/A1:2000
Product Standard
EN 301 489-17
Surge wave form (Tr/Th)
:
1, 2/50
(
8/20
)
µ
s
Level
:
on Signal ports And Telecommunication – N/A
on Input AC Power Port -- 2
Test Voltage
:
on Signal ports And Telecommunication – N/A
on Input AC Power Port --
±
1.0 KV
Temperature :
25
°
C
Relative Humidity
:
60 %
Test Date
:
Nov. 28, 2003
Remark
:
“ N “ means the EUT function was correct during the test.
Angle
;
0
°
;
90
°
;
180
°
;
270
°
;
360
°
Voltage ( KV ): 0.5 kV
Test Location: L-N
Test Result: PASS
26.1.
TEST LEVEL
\Phase
\Voltage \Mode \Polarity \Result
0
°
90
°
180
°
270
°
360
°
+ N N N N N
0.5 kV
L-N
- N N N N N
Note: “N” means the EUT function was correct during the test.