E
xclusive
C
ertification
C
orp
.
Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
16 of 16
EMC
Test Report: CE03111004-A
9. Test on Power Line (EFT)
a. The EFT/B-generator was located on the GRP.. The length from the EFT/B-generator to the EUT as
not exceed 1 m.
b. The EFT/B-generator provides the ability to apply the test voltage in a non-symmetrical condition to
the power supply input terminals of the EUT..
9.1.
Test on Communication Lines
a.
The coupling clamp is composed of a clamp unit for housing the cable (length more than 3 m), and
was placed on the GRP
.
b.
The coupling clamp provides the ability of coupling the fast transient/bursts to the cable under test
.
9.2.
Test Procedure
a. In order to minimize the effect of environmental parameters on test results, the climatic
conditions when test is carrying out shall comply with the following requirements:
ambient temperature: 15 to 35 ;
℃
℃
relative humidity : 45
%
to 75
%
;
atmospheric pressure : 68 Kpa (680 mbar) to 106 Kpa (1060 mbar).
b. In order to minimize the effect of environmental parameters on test results, the electromagnetic
environment of the laboratory shall not influence the test results.
c. The variety and diversity of equipment and systems to be tested make it difficult to establish
general criteria for the evaluation of the effects of fast transients/bursts on equipment and
systems.
d. The test results may be classified on the basic of the operating conditions and the functional
specification of the equipment under test, according to the following performance criteria :
Normal performance within the specification limits.
Temporary degradation or loss of function or performance which is self-recoverable.
Temporary degradation or loss of function or performance which requires operator
intervention or system reset.
Degradation or loss of function which is not recoverable due to damage of equipment
(components).