Issued date: Dec. 16, 2003
57 of 57
EMC
Test Report: CE03111004-A
25. Electrical Fast Transient/Burst Immunity Test (EFT/BURST)
Final Test Result
:
PASS
Pass performance Criteria
: CT/CR
Required performance criteria : TT/TR
Basic Standard
: EN61000-4-4:1995/A1:200
Product Standard
EN 301 489-17
Level
:
2
Test Voltage
:
on Power Supply --
±
1.0 KV
on I/O signal, data and control line --
±
0.5 KV
Temperature :
25
°
C
Relative Humidity
:
60 %
Test Date
:
Nov. 28, 2003
Observation :
Normal
25.1.
Test Severity Levels
0.5 kV
1.0 kV
\Voltage\Polarity
\Test Point\Mode\Result
+ - + -
L N N N N
N N N N N
Power Line
L-N N N N N
LAN Line
N
N
---
---
Note: “N” means the EUT function was correct during the test.
“---“means the test could not be carrier out.