E
xclusive
C
ertification
C
orp
.
Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
10 of 10
EMC
Test Report: CE03111004-A
4.2.
Typical Test Setup Layout of Radiated Emission
4.3.
Radiated Emission Requirement
The EUT shall meet limits of tables as below when measured at the measuring distance R in
accordance with the methods described in clause 10. If the reading on the measuring receiver
shows fluctuations close to the limit, the reading shall be observed for at least 15 s at each isolated
high reading, which shall be ignored.
Limit for radiated disturbance of class B ITE at a measuring distance of 10 m
Frequency
(MHz)
Quasi-peak limits
dB (uV/m)
30 to 230
30
230 to 1000
37
Note 1- The lower limit shall apply at the transition frequency.
2- Additional provisions may be required for cases where interference
occurs.
Turn Table
0.8M
Equipment under Test
Ground Plane
Receiver
* Test distance
Antenna