15 of 20
FIG.11: Daisy chain of tubes
Installation engineer should use appropriate plugs for
outdoor connection.
DMX In
AC In
300mm
LED Engine 240W 48V
Starter Cable
TUBES ARE DAISY CHAINED
Sig
nal
48V
DMX
-
DMX+
Gr
ound
W
ire Siz
e
AWG 17
AWG 24
AWG 24
AWG 17
Color
Red
Gr
een
Blue
Black
This wiring diagram shows only typical connections. Actual wiring depends on LED Tube configuration and installation.
Actual no. vary according to cable lengths and signal
source. Please consult your local Traxon office for aid.
End Cap
LED Solution
Max. Connection Quantity
RGBW 4 in 1
12
RGB + W
12
RGB
14
DW
14