www.traxontechnologies.com
©2020 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U.
PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide
IG0107EN V1.0 09/20
8 of 20
2.3 On-Site Installation
•
DO NOT attempt installation in wet or severe weather conditions.
•
DO NOT leave and expose any ARCHISHAPE
®
Tube Ultra Slim or LED
Engines unconnected under wet/raining or snowing environment.
•
IP failure induced by stressed/damaged cables during or after installation
will not be under warranty by Traxon Technologies.
•
ALWAYS keep the cables protected from sharp objects and ensure no
damage is generated on the cable.
Failure to keep ARCHISHAPE
®
Tube Ultra Slim within the operating temperature range of
–25°C to +50°C / –13°F to +122°F and storage temperature range of –40°C to +70°C /
–40°F to +158°F will void the product’s warranty.
2.3.1
On-Site Installation
1. Fix brackets to installation surface with anchor bolts.
FIG.6: Fixing the Mounting Clip to Installation Surface
Tube-to-Tube Clearance
To maintain consistent LED pitch and to allow for thermal expansion for Media Tubes.
End Cap Seal on Last Tube
>4~10mm
Bracket mounting
1
2
ST3.5mm (x 4)
(Not included)
2. The ARCHISHAPE
®
Tube Ultra Slim are interconnected using the IN and OUT cables on
each end of the tube. Screw the connectors tightly for a water-tight seal. Below diagram
shows the Tube connections. Always remember to affix an Quick Lock Waterproof End
Cap (sold separately) for the OUT connector of the final Tube in each daisy chain. See
System Diagram for details.
FIG.7: ARCHISHAPE
®
Tube Ultra Slim Connections
TUBES ARE DAISY CHAINED
Signal
48V
DMX-
DMX+
Ground
Wire Size
AWG 17
AWG 24
AWG 24
AWG 17
Color
Red
Green
Blue
Black
DMX In
300mm
LED Engine 150W 48V
AC In
Installation engineer should
use appropriate plugs for
outdoor connection.
Ethernet
Source
Ethernet Switch
LCE2 fx
TUBE INTERCONNECTION
Starter Cable
End Cap
This wiring diagram shows only typical connections. Actual wiring depends on LED Tube configuration and installation.
*Max. no. fixtures is 96 for DMX signal / 32 for e:pix signal. Actual no. vary according to cable lengths and signal
source. Please consult your local Traxon office for aid.