www.traxontechnologies.com
©2020 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U.
PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide
IG0107EN V1.0 09/20
12 of 20
4.2 LED CONTROL
The LEDs on the ARCHISHAPE
®
Tube Ultra Slim are controlled by DMX512. Each pixel on
the Tube uses three RGB 3 in 1 LEDs and three white LEDs with twelve channels, for R, G, B
and W. Pixel number 1 begin on the IN connector side, and it uses the first four channels. The
start address is the next address from the previous tube in the daisy chain.
1 RGBW 4 in 1 Pixel
RGBW 4 in 1 LED
RGBW
Pixel n
Control Channel Number
R
Tube start a4(n-1)
G
Tube start a4(n-1) + 1
B
Tube start a4(n-1) + 2
W
Tube start a4(n-1) + 3
Where: n is pixel number along the Tube.
(Pixel 1 is located near the IN connector.)