Gas Appliance Receiver Wire Installation
We recommend the receiver wires to be installed in a parallel circuit with the on/off switch. See the directions
below for this type of installation.
Back of on/off switch
Remove the two wires from
the back of the on/off
switch.
a
c
Attach the wires removed in step A to the “Y”
jumpers then attach the jumpers to one side of the
on/off switch (orientation does not matter).
“Y” Jumper Wires
Attach the receiver wires to
the “Y” jumpers (orientation
does not matter).
Receiver
Wires
b
Pellet Appliance Receiver Wire Installation
The receiver wires connect to the back of the pellet control board. See the directions below for installation.
b
Swing the
panel
open.
d
a
Phillips
Screwdriver
Open the hopper lid and remove the
screw holding the right panel in place.
Route the wires up to the circuit
board and attach the quick-connects
to the thermostat posts (orientation
does not mater).
Bundle up any excess wire with a
lock-tie to prevent it from contacting
any hot or moving parts
If necessary, attach the
pellet stove connector
wires to the ends of the
receiver wires.
c