© Travis Industries, Inc.  

Compatibility 

 

All Travis Gas Stoves 

 

33 DVI Insert 

 

31 DVI Insert 

 

564 SS GS 

 

864 TRV GS 

 

864 ST GS 

 

All Travis Pellet Stoves or Inserts 

Packing List 

 Transmitter 

 

 Receiver 

 Receiver 

Hanger 

 

Pellet Stove Connector Wires 

 

“Y” Jumper Wires (for gas appliances) 

 

Power Cord Adapter (for gas appliances) 

FCC Requirements 

Warning

: Changes or modifications to this unit not expressly approved by the party responsible for 

compliance could void the user's authority to operate the equipment.  This equipment has been tested and 
found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These 
limits are designed to provide reasonable protection against harmful interference in a residential installation.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions,, may cause harmful interference to radio communications.  However, there 
is no guarantee that interference will not occur in a particular installation.  If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

- Reorient or relocate the receiver. 

- Increase the separation between the equipment and receiver. 

- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

- Consult the dealer or an experienced radio TV technician for help. 

Canadian Equipment Requirements 

This digital apparatus does not exceed the (Class A/Class B) limits for radio noise emissions from 
digital apparatus set out in the Radio Interference Regulations of the Canadian Department of 
Communications.  Le present appareil numerique n'emet pas de bruits radioelectricques depassant les 
limites applicables aux appareils numeriques (de la class A/de la class B) prescrites dans le Reglement 
sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. 

This device complies with RSS-210 of Industry and Science Canada.  Operation is subject to the 
following two conditions: (1) this device may not cause interference, and (2) this device must accept 
any interference, including interference that may cause undesired operation of the device. 

Installation Warnings 

!  Shut off power to the appliance and allow it to cool prior to installation. 

!  This kit must be installed by a qualified technician. 

!  All 110 VAC wiring must be done by a qualified electrician and shall be in compliance with local 

codes and the National Electric Code ANSI/NFPA No. 70 (in the United States), or with the current 
CSA C22.1 Canadian Electric Code (in Canada). 

!  Do not connect 110 VAC to the gas control valve or on/off switch on gas heaters or the thermostat 

posts on pellet heaters. 

Follow the instructions on the following pages for the type of model being addressed. 

Содержание SKU 99300646

Страница 1: ...tion between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian Equipment Requirements This digital apparatus does not exceed the Class A Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulati...

Страница 2: ...er with the wires exiting the rear Stoves with the on off switch in front Make sure the wires do not contact the burner pan or moving parts use lock ties of necessary Gas or Pellet Fireplace Insert Receiver Placement Place the receiver behind the surround panel on the fireplace floor see the illustration to the right Route the receiver wires to a location near the on off switch Connect the receive...

Страница 3: ... the blower if applicable or firebox or other hot surface Use lock ties if necessary Place the receiver in a location near the front of the fireplace Power Cord Adapter Installation On newer gas appliances power may be drawn directly from the appliance AC circuit Connect the receiver power cord to the power cord adapter then attach to the power harness on the appliance see illustration below If us...

Страница 4: ...ot matter Y Jumper Wires Attach the receiver wires to the Y jumpers orientation does not matter Receiver Wires b Pellet Appliance Receiver Wire Installation The receiver wires connect to the back of the pellet control board See the directions below for installation b Swing the panel open d a Phillips Screwdriver Open the hopper lid and remove the screw holding the right panel in place Route the wi...

Страница 5: ...s indicates the transmitter and receiver are calibrated on the same radio frequency if it does not remove batteries replace and repeat this process Test operation of the remote control Receiver RO OM TE M P F F SE T TE MP PM Se t Tim e Ca nc el M A N U A L O N O F F A TO U N F O O F Flam e Heig ht Fan Spe ed Beep Setting the Time ON ROOM TEMP F F SET TEMP TIMER MIN TIMER CLOCK UP and Down Arrows 1...

Страница 6: ...imed for the remote to work correctly NOTE The remote must be calibrated before it will work see the instructions on the previous page If the remote fails to work try unplugging the remote receiver plugging it back in then re calibrate the remote MODES OF OPERATION Manual Mode Use manual mode to turn the heater on and off directly OFF ROOM TEMP F F SET TEMP TIMER MIN TO TURN ON AND OFF Use this ke...

Страница 7: ... the heater does not turn on do not adjust the target temperature the heater will turn on in a few minutes The thermostat is not intended for un attended use If the thermostat calls for heat for 6 hours continuously it will shut off and not turn on until reset HINT If your heater turns on and off frequently adjust the flame height down slightly for a more consistent heat output TIMER CLOCK MANUAL ...

Страница 8: ... in the following order UP DOWN DOWN UP DOWN TIMER CLOCK MANUAL O N O F F O N OF F AU T O Press these buttons OPERATION WITH DEAD BATTERIES If the heater is on any mode and the batteries go dead the heater will turn off after 6 hours To operate the heater use the switch on the heater to turn the heater on and off TURNING THE UNIT OFF WHEN TRANSMITTER IS NOT PRESENT If at any time you misplace the ...

Отзывы: