Installation
(for qualified installers only)
41
© Travis Industries
4090709
100-01222_000
Installation Example - Build-Out (Dog-House) with Hor. Termination
•
The framing, facing, and other building materials depicted below are for example only. Refer to local
building codes for framing, facing, and insulating requirements in your area.
Side View
Top View
See "Vent Termination"
for full requirements.
4'' (102mm) Section*
Firestop
NOTE FOR 2 x 4 (51mm X 102mm) EXTERIOR
WALLS:
When installed with a 2x4 (51mm X 102mm)
exterior wall, the termination may not fit flush against
the exterior wall. You may wish to place framing
around the termination to fill the gap.
SIDE OF FIREPLACE
Horizontal Termination*
* Travis Ind. MIn. Vent Kit (SKU 98900168) Includes
a 4'' (102mm) section and horizontal termination.
Drywall
Optional Tile
NOTE
: If required to use drywall inside
the firebox enclosure, make sure to alter
the framing accordingly.
NOTE
:
In colder climates the fireplace may
require an insulated enclosure.
Insulation
Drywall
Optional Tile
Vapor
Barrier
NOTE
:
1/2'' (13mm) Clearance to
sides and back of fireplace.