Installation
(for qualified installers only)
13
© Travis Industries
4140221
100-01345
Minimum Framing Dimensions - Rear Vent Configuration
24-1/4"
616mm
36-1/2"
927mm
33-1/2"
851mm
16-1/2"
419mm
Route the
electrical line to
a position to the
left rear of the
fireplace.
Vent Clearances for 8" (203mm) dia. Vent:
1" (25mm) to the sides, 1" (25mm) below,
and 4" (102mm) above the vent to
combustibles.
Included Firestop (required)
Part # 250-00747
Center of Rear Vent
HINT: place the fireplace so the center
line is at least 5" (127mm) from both
vertical framing members at the rear (this
allows the vent to pass through the
framing without modfications)
Minimum 38" (965mm)
Fireplace Enclosure Height
19-1/4"
489mm
32-1/2"
826mm