42 Installation
(for qualified installers only)
© Travis Industries
4140221
100-01345
Installation Example - Build-In with Horizontal Termination
The framing, facing, and other building materials depicted below are for example only. Refer to local
building codes for framing, facing, and insulating requirements in your area.
Side View
Top View
See "Vent Termination"
for full requirements.
4'' (102mm) Section*
NOTE FOR 2 x 4 (51mm X 102mm) EXTERIOR
WALLS:
When installed with a 2x4 (51mm X 102mm)
exterior wall, the termination may not fit flush against
the exterior wall. You may wish to place framing
around the termination to fill the gap.
SIDE OF FIREPLACE
Horizontal Termination*
NOTE
: If required to use drywall inside
the firebox enclosure, make sure to alter
the framing accordingly.
NOTE
:
1/2'' (13mm) Clearance to
sides and back of fireplace.
Insulation
Drywall
Optional Tile
Drywall
Optional Tile
Firestop
(make sure all vent clearances are met)