10 Installation
(for qualified installers only)
© Travis Industries
4140221
100-01345
Top Vent or Rear Vent Configuration
This appliance is shipped in the rear vent configuration. To change to the top vent configuration, follow
the directions below.
NOTE
: the vent configuration affects several aspects of installation (framing, maximum vent rise,
maximum vent run). Make sure the vent configuration is correct prior to installation. You may wish to
configure the diffuser when changing the vent configuration.
Converting the Fireplace to Top Vent Configuration
Remove the 4 screws securing the
outer flue assembly. Place the
screws and assembly aside.
NOTE: Use a magnetic-tipped
nutdriver on these screws - take
care to prevent the screws from
falling into the fireplace.
Top of Fireplace
Back of Fireplace
Remove and discard the
heat shield. Replace the 4
removed screws.
Remove the 4 screws securing the
inner flue assembly. Place the
screws and assembly aside.
Remove the 4 screws securing the
intake cover plate. Place the screws
and cover plate aside.
Remove and discard the
insulation found below the
large cover plate.