Installation
(for qualified installers only)
23
© Travis Industries
4140221
100-01345
Approved Vent Configurations
Restrictor Position
Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and
exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor
positions. The charts for acceptable vent configurations detail the correct vent restrictor positions.
Exhaust Restrictor Adjustment
If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while the exhaust
restrictor is removed.
In this example, the restrictor is
set in position # 3.
(closed) #6
# 5
# 4
# 3
# 2
# 1
(open - stock position) # 0
Back of Firebox
Back Wall of Firebox
Firebox Roof
The exhaust restrictor is shipped
in postion # 0. If the restritor is
required in a different postion,
remove the screws, re-position
the restrictor (see the illustration
below), and replace the screws.