Finalizing the Installation
(for qualified installers only)
41
© Travis Industries
4090807
100-01193_003
7. Check the air shutter following the directions below.
Air Shutter Adjustment
Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should
be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.
Correct
Flames should be blue at the
base, yellow-orange on the top.
If the flames are too tall or sooty on the
ends, open the air shutter.
Not Enough Air
If the flames are all blue and
short, close the air shutter.
Too Much Air
How to Adjust the Air Shutter
The air shutter is located to the left of the burner and is accessed by removing the glass frame (see the
illustration below). The air shutter lever may be adjusted with the logs in place – a screwdriver of other
tool may be used to “tap” the lever to the desired position. After adjusting the air shutter replace the
glass and verify flame quality.
Air Shutter Lever
Closed
Open
Suggested Min. Air Shutter Settings:
NG
1/8” Open (1/8” from the left)
LP
1/2” Open (1/2” from the left)
8. Adjust the flame height to its highest position - the flames should not contact the top of the
firebox. Check the flame on lowest position. The flames should burn off each burner hole. If
the heater does not work correctly, contact your Travis dealer for a remedy.
9. Give this manual to the home owner for future reference and fully explain operation of this
heater. For comprehensive operating and maintenance instructions, refer to the Owner's
Manual (part # 100-01194).