Accent Light Electrical Connection
Make sure power to the heater has been turned off prior to installation (disable the breaker).
Do not connect 110-120 VAC to the gas control valve or the on/off circuit on this fireplace.
•
The electrical line must be installed by a qualified installer and must meet all local codes.
•
The optional accent light requires a 110v circuit wired through a junction box to the fireplace.
See the illustration below for details.
Junction Box
(not supplied)
Insulated Wire (Romex)
Do not route the wires over the top
of the fireplace.
Power Supply
(110v ac)
Cover Plate on Control Box
(see instructions below)
Rheostat (included)
Cover Plate (included)
Knob (included)
Wiring Schematic
Rheostat Junction Box
Accent Lights
Power Supply
Hot
(black)
Common
(white)
Ground
(green)
Hot
(black)
Common
(white)
Ground
(green)
Fireplace Junction Box
Accent
Light
Molex
Connector
The wiring for the accent light is best installed
prior to drywall installation around the fireplace.
All electrical connections must be made by a
qualified installer and must meet all local codes.
Remove one of the knock-outs on the cover
plate and pass the wiring through the cover
plate (use the romex connector included with
the accent light). Attach the hot and common
wire from the accent light switched power
supply to the black and white wire leading from
the molex connector. Attach the ground wire to
the grounding tab on the receptacle.
Fireplace Power Supply
(attached to receptacle)
Control Box
Cover Plate
Romex
Connectors
Accent Light Switched
Power Supply