background image

10BASE-T/100BASE-TX to 100BASE-FX

Bridging Media Converter 

C/E-PSW-FX-03, C/E-PSW-FX-03(SC), C/E-PSW-FX-03(SM)

C/E-PSW-FX-03(LH), C/E-PSW-FX-03(XL), C/E-PSW-FX-03(LW)

USER’S GUIDE

TRANSITION Networks C/E-PSW-FX-03 series two-port bridging media
converter, designed to be installed in the TRANSITION Networks Media
Conversion Center, E-MCC-1600, segments 10BASE-T/100BASE-TX copper
and 100BASE-FX fiber Ethernet

collision domains to allow the network

administrator to extend the total network diameter, to reduce network
congestion, and/or to convert between legacy 10BASE-T and 100BASE-FX
environments. 

COMPLIANCE INFORMATION

UL Listed 
C-UL Listed (Canada)
CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.  This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.  Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on
the radio interference regulations of the Canadian Department of Communications.

Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables

aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.

European Regulations

Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen
werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques
appropriées

Trademark Notice

All registered trademarks and trademarks are the property of their respective owners.

Copyright Restrictions

© 1999-2001 TRANSITION Networks.
All rights reserved.  No part of this work may be reproduced or used in any form or by any means –
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A.

33102.D

CAUTION:  RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität. 

C/E-PSW-FX-03 
Provides an RJ-45 twisted-pair
connector to UTP/STP copper cable
and a set of RX (receive) and TX
(transmit) ST 1300nm multimode
fiber connectors.

C/E-PSW-FX-03(SC) 
Provides an RJ-45 twisted-pair
connector to UTP/STP copper
cable and an RX (receive) and TX
(transmit) SC 1300nm multimode
fiber connector.

C/E-PSW-FX-03(SM) 
Provides an RJ-45 twisted-pair
connector to UTP/STP copper
cable and an RX (receive) and TX
(transmit) SC 1300nm singlemode
fiber connector.

C/E-PSW-FX-03(LH) 
Provides an RJ-45 twisted-pair
connector to UTP/STP copper
cable and an RX (receive) and TX
(transmit) SC 1300nm singlemode
fiber connector.

C/E-PSW-FX-03(XL) 
Provides an RJ-45 twisted-pair
connector to UTP/STP copper
cable and an RX (receive) and TX
(transmit) SC 1300nm singlemode
fiber connector.

C/E-PSW-FX-03(LW) 
Provides an RJ-45 twisted-pair
connector to UTP/STP copper
cable and an RX (receive) and TX
(transmit) SC 1550nm singlemode
fiber connector.

C/E-PSW-FX-03 in the Network  . . . .2
Installation  . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . .11
Fault Isolation and Correction  . . . .12
Cable Specifications  . . . . . . . . . . . .13
Technical Specifications  . . . . . . . . .15
Compliance Information . . . . . . . . .16

Содержание C/E-PSW-FX-03

Страница 1: ...nkstörungen auftreten in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de créer des interférences radioélectriques il appartiendra alors à l utilsateur de prende les measures spécifiques appropriées Trademark Notice All registered trademarks and trademarks are the property o...

Страница 2: ...n Networks 6475 City West Parkway Minneapolis MN 55344 USA Model C E PSW FX 03 Series Bridging Media Converter Part Number C E PSW FX 03 C E PSW FX 03 SC C E PSW FX 03 SM C E PSW FX 03 LH C E PSW FX 03 LW C E PSW FX 03 XL Regulation EMC Directive 89 336 EEC Purpose To declare that the E PSW FX 03 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class...

Страница 3: ...P If the receiving switch is capable of 10BASE T communication only the FLPs are ignored and the cable segment operates as 10BASE T If the device can support 100BASE TX operation the bridging media converter detects the FLPs uses the auto negotiation algorithm and FLP data to determine the highest possible cable segment speed and mode and automatically places both the device and the bridging media...

Страница 4: ...for a later upgrade to 100BASE TX DO NOT USE FLAT OR SILVER SATIN WIRE 100BASE TX The physical characteristics of 100BASE TX cable must meet or exceed IEEE 802 3 100BASE TX specifications Category 5 cable or better is required Either shielded twisted pair STP or unshielded twisted pair UTP can be used DO NOT USE FLAT OR SILVER SATIN WIRE Category 3 Gauge 24 to 22 AWG Attenuation 6 5 dB 100 10 MHz ...

Страница 5: ...connect the fiber cable to restart the initialization process Restart the terminal device s to restart the initialization process Refer to Tech Tips available at http www transition com Contact Technical Support 800 260 1312 YES Contact Technical Support 800 260 1312 TWISTED PAIR AUTO NEGOTIATION Set auto negotiation DIP switch 1 to select auto negotiation ON UP Set twisted pair full duplex half d...

Страница 6: ...Slide in Module into installation slot aligning Media Converter Slide in Module with installation guides NOTE Ensure that the Media Converter Slide in Module is seated firmly against the backplane 3 Secure Slide in Module to E MCC 1600 chassis by rotating captive screw attached to Slide in Module clockwise into chassis OPERATION Use the status indicator LEDs to monitor C E PSW FX 03 operation in t...

Страница 7: ...ound arrow 3 Connect other end of cable installed at transmit TX connector of bridging media converter to receive RX connector on network device connect other end of cable installed at receive RX connector of bridging media converter to transmit TX connector on network device Powering the Bridging Media Converter NOTE The Slide In Module is powered through the Media Conversion Center Using the 5 S...

Страница 8: ...T AND THE ETHERNET COLLISION DOMAIN Refer to the 5 Segment Rule page 8 before installing half duplex 10BASE T cable Installing full duplex twisted pair cable avoids collision domain considerations distances remain 100 meters 100BASE TX AND THE FAST ETHERNET COLLISION DOMAIN Refer to the 512 Bit Rule before installing half duplex 100BASE TX cable Installing full duplex twisted pair cable avoids col...

Страница 9: ......

Отзывы: