AR2200 RF Module User Guide
3-6
Figure 3-2 RF Module Terminal Connections
Grounding the RF Module
The CHASSIS terminal is electrically connected to case ground at the factory. Case
ground must be connected to earth ground. TransCore does not recommend that a
conduit connection be used as a grounding point. Ground points must make metal-to-
metal connections.
Note: TransCore does not recommend grounding the case through nonconducting
finishes, such as paint, anodize, or irudite.
Refer to the reader documentation for further information concerning grounding. The
CHASSIS terminal jack is shown in Figure 3-2.