USER MENU DESCRIPTIONS 

 
This section provides more detailed descriptions of the selections found in the User Menu Chart.  
Factory-set defaults are shown in bold; (NA) for North America and (

) for Europe. 

 

CODE/NAME 

DESCRIPTION 

SELECTION LIST 

A1 
Baud Rate 

Selects the baud rate for data transmission through the serial port. 

300, 600, 1200, 
2400, 4800,  
9600 (NA/€)
19200, 38400 

A2 
Data Bits and 
Parity 

Selects the number of data bits and parity of serial transmission. 

"8n" = 8 data bits with no parity bit and one stop bit 

"7O" = 7 data bits with odd parity bit and one stop bit 

"7E" = 7 data bits with even parity bit and one stop bit 

"7n" = 7 data bits with no parity bit and two stop bits 

8n (NA/€) 
7O 
7E 
7n 

A3 
Serial Port 
Mode 

Selects the mode of the I/O serial port: Refer to Appendix B for more 
information. 

"d" = Demand Duplex 

"C" = Continuous Duplex 

"Auto" = Auto Print 

“3” = Test and Measurement 

d (NA/€) 

Auto 

A4 

Diagnostics 

Actuates  the  function  that  illuminates  all  digit  segments,  decimal 
points, and LED annunciators in a test sequence. 

Press ZERO key 
to begin sequence 

A6 
Output String  

Loads in a pre-defined output string (print format) for the serial port. 
Refer to Appendix B for details. 

"0" = Text Print Ticket 

"1" = String Format 1 (Condec Demand) 

"2" = String Format 2 (Condec Continuous)\ 

“3” = Text Print Ticket with MP-20 Auto Label Feed 

0

√√

 (NA/€) 



A8 
ID No. Entry 

Actuates the function that allows entry of a new ID No. Pressing the 
ZERO key to scroll down one level begins the sequence. 

0 – 999999 
99 (NA/€) 

A14 
Time Format 

Selects the printed format for time. 

"0" = AM/PM                                    "1" = 24 Hr 

0

√√

 (NA) 

1

√√

 (€) 

 

A15 
Set Time 

Actuates  the  function  that  allows  setting  the  time.  Pressing  the 
ZERO key to scroll down one level begins the test sequence. 

Press ZERO key 
to begin sequence 

A16 
Set Date 

Actuates  the  function  that  allows  setting  of  the  date.  Pressing  the 
ZERO key to scroll down one level begins the test sequence. 

Press ZERO key 
to begin sequence 

A17 
Date Format 

Selects the printed format for date. 

"1" = mm/dd/yy       "2" = dd/mm/20yy          “3” = dd/mm/yy 

"4" = dd/mm/20yy       "5" = yy/mm/dd            “6” = 20yy/mm/dd 

1

√√

 (NA)       

3

√√

 (€)          

5                 6 

A31 
Edit Output 
String  

Actuates the function that allows editing of output string. Pressing 
the ZERO key to scroll down one level begins the test sequence. 

Press ZERO key 
to begin sequence 

A34 
Decimal Point  

Selects printed (not displayed) decimal point character.  

"0" = Period (‘.’)                       "1" = Comma (‘,’) 

0 (NA) 
1 (€) 

Содержание TI-1520

Страница 1: ...MODEL TI 1520 Digital Weight Indicator User Manual Revision 1 8 August 3 2012...

Страница 2: ...EW CALIBRATION VALUES F18 12 KEY IN ZERO CALIBRATION VALUE F19 13 KEY IN SPAN CALIBRATION VALUE F20 13 OPERATION 14 DISPLAY 14 KEYBOARD 15 FUNCTION KEYS 15 GENERAL SCALE OPERATION 15 WEIGHING AN ITEM...

Страница 3: ...idential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio com...

Страница 4: ...ssible In extreme cases it may be necessary to install surge suppressors line conditioners or even UPS Uninterruptible Power Supplies systems not included Environment Avoid installing the indicator in...

Страница 5: ...o the green load cell input terminal The TI 1520 indicator contains a connection terminal on the main board for connection to the load cell cable Connect your shielded load cell cable not included to...

Страница 6: ...The Setup and User menus consist of several menu selections each with its own sub menu of selections or programming procedures To configure the indicator you must first enter the appropriate menu mode...

Страница 7: ...S This section provides more detailed descriptions of the selections found in the Setup Menu Chart Factory set defaults are shown in bold NA for North America and for Europe NOTE Some selections are s...

Страница 8: ...al point 0 NA 0 0 0 00 0 000 0 0000 00 F14 Units Conversion Allows the lb kg key to be disabled so that an operator cannot accidentally press the key and change the displayed units 0 Disable the Units...

Страница 9: ...0 0 NA 10 F32 Center of Zero Band Selects the range around gross zero within which the scale will display the Center of Zero annunciator Selections are in display divisions d 0 25d US 0 5d F34 Auto Pr...

Страница 10: ...Loads in a pre defined output string print format for the serial port Refer to Appendix B for details 0 Text Print Ticket 1 String Format 1 Condec Demand 2 String Format 2 Condec Continuous 3 Text Pri...

Страница 11: ...alue Increase the flashing digit by pressing the UNITS key Decrease the flashing digit by pressing the ZERO key Pressing the PRINT key or the TARE key will change the position of the flashing digit 4...

Страница 12: ...3 Use the four directional keys to adjust the displayed value to the actual date value Increase the flashing digit by pressing the UNITS key Decrease the flashing digit by pressing the ZERO key Press...

Страница 13: ...troubleshoot setup problems 2 After making sure that there are no test weights on the platform press the ZERO key again to zero out the displayed value 3 Press the NET GROSS key to save the zero point...

Страница 14: ...causes include incorrect load cell wiring a mechanical obstruction or a faulty load cell VIEW CALIBRATION VALUES F18 Note The values displayed in this procedure are valid only after a successful cali...

Страница 15: ...id span calibration values obtained from a successful F17 calibration procedure must be used 1 While in the Setup mode scroll to F 20 and then scroll down once using the ZERO key The indicator will pr...

Страница 16: ...ever the displayed weight is within a pre programmed band from true zero NET Indicates that the indicator is displaying net weight GROSS Indicates that the indicator is displaying gross weight TARE In...

Страница 17: ...scale is not in overload see Appendix D for error codes Print This key is used to send weight information out to the serial port provided the following conditions are met 1 The scale is not in motion...

Страница 18: ...u continue to push the UNITS key the indicator will resort back to weighing mode and you must start again from Step 2 3 Place the sample items on the platform all at once and allow the weight indicati...

Страница 19: ...20 continuously and at the same transmission baud rate configured in A1 LEGAL FOR TRADE SEALING Indicators can be sealed for commercial Legal for Trade applications as follows 1 On the back of the ind...

Страница 20: ...56 x 8 external to C Digital Filtering Software selectable SERIAL COMMUNICATIONS Serial Port Full Duplex selectable Baud rate 8 data bits no parity 1 stop bit 7 data bits odd parity 1 stop bit 7 data...

Страница 21: ...tor to zero the scale The indicator will not respond if the scale is in motion positive overload or negative overload The indicator will also not respond if it is in net mode or outside the zero range...

Страница 22: ...ht TWT 131 83 Print the data on screen CWT 132 85 Units lb kg PCS UN 133 86 Date DAT 134 87 Time TIM 135 88 O Over Under M Motion STAT 136 89 Gross Net flag G N GN 137 8A MP20 printer to print header...

Страница 23: ...02 2E 31 53 S 03 4E N 32 80 GWT 04 4F O 33 85 UN 05 2E 34 0D CR 06 8C PRID 35 0A LF 07 0D CR 36 54 T 08 0A LF 37 41 A 09 44 D 38 52 R 10 41 A 39 45 E 11 54 T 40 20 12 45 E 41 82 TWT 13 8E PRSPS 42 85...

Страница 24: ...larity SP Positive Negative Weight Data Units LB pound KG kilogram Gross Net GR Gross NT Net Start Transmission Carriage Return Line Feed SP SP Space Space pc pieces cu cusotm unit pcs pieces Address...

Страница 25: ...F Polarity SP Positive Negative Weight Data Units L pound K kilogram Gross Net G Gross N Net Start Transmission Carriage Return Line Feed Status SP Valid M Motion O Over under range P pieces C custom...

Страница 26: ...rrow key PRINT to increase the address by one Use the left arrow key TARE to decrease the address by one 3 After selecting the address you want to change press the NET GROSS key The programming value...

Страница 27: ...Keyed in weight value is less than 1 of full scale capacity Use a larger test weight or check keyed in value Err 2 Span Calibration Mode F17 There is not enough load cell signal to produce the intern...