![Trane TZEMT400 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/trane/tzemt400/tzemt400_installation-instructions-manual_1150378013.webp)
13
18A
Gas Furnace - Multistage Mechanical Settings
a. Press the MENU button twice.
b. Press and hold the two inner buttons for 3 seconds to view
Installer Settings.
c. Scroll down to System Settings and press the Select button.
d. Scroll to Mechanical Settings (it is the first option), then press the
Select button.
e. Scroll down to 2nd Stage Heat.
f.
Press the + button to change the setting to Y for Yes.
g. If your system also has 2nd stage cooling, scroll down to 2nd
Stage Cool and Press the + button to change the setting to Y for
Yes.
h. Press the Done button 4 times and go to step 19.
Menu
button
MENU MODE FAN RUN
75
76 H
74 C
11:15 AM
Two inner
buttons
18B
Electric Furnace Mechanical Settings
a. Press the
MENU
button twice.
b. Press and hold the two inner buttons for 3 seconds to view
Installer Settings
.
c. Scroll down to
System Settings
and press the
Select
button.
d. Scroll to
Mechanical Settings
(it is the first option), then press
the
Select
button.
e. Scroll down to
Fan Type
.
f.
Press the
+
button to change the setting
Electric
.
Î
Î
If Single Stage System, press Done 4 times and go to step
19.
Î
Î
If Multistage System, continue with steps “g” through “j”.
g. Scroll down to 2nd Stage Heat.
h. Press the + button to change the setting to Y for Yes.
i.
If your system also has 2nd stage cooling, scroll down to 2nd
Stage Cool and Press the + button to change the setting to Y for
Yes.
j.
Press the Done button 4 times and go to step 19.
Select
button
Scroll
up
Scroll
down
+
button
Done
Mechanical Settings
Select
Type Heatpump
Fan Type Elec
C/O Type w/Cool
2nd Stage Heat N
18C
Heat Pump Mechanical Settings
a. Press the MENU button twice.
b. Press and hold the two inner buttons for 3 seconds to view
Installer Settings.
c. Scroll down to System Settings and press the Select button.
d. Scroll to Mechanical Settings (it is the first option), then press the
Select button.
e. Scroll to system Type.
f.
Press the + button to change the setting to Heat Pump.
g. Scroll down to Fan Type.
h. Press the + button to change the setting Electric.
i.
If Coleman, Rheem, or Rudd brand heat pump, scroll to C/O Type
and change to With Heat.
Î
Î
If Single Stage System, press Done 4 times and go to step
19.
Î
Î
If Multistage System, continue with steps “j” through “n”.
j.
Scroll down to 2nd Stage Heat.
k. Press the + button to change the setting to Y for Yes.
l.
Scroll down to 2nd Stage Cool.
m. Press the + button to change the setting to Y for Yes.
n. Press the Done button 4 times and go to step 19.