UNT-PRC002-GB
Technical Data
FWD
08
12
20
30
45
Power supply
(V/Ph/Hz)
230/1/50
Capacities
Cooling capacity on water (1)
(kW)
5,2
8,3
15
18,8
30,1
Heating capacity on water (2)
(kW)
6,3
11,9
18,9
20,9
38,2
Fan motor
(type)
2 x direct drive centrifugal
Fan power input (3)
(kW)
0,23
0,46
0,65
1,04
1,51
Current amps (3)
(A)
1,1
2,2
3,1
4,7
5,5
Start-up amps
(A)
3,2
5,5
9,3
14,1
16,5
Air flow
minimum
(m
3
/h)
490
980
1400
1800
2700
nominal
(m
3
/h)
820
1650
2300
3000
4500
maximum
(m
3
/h)
980
1970
2600
3600
5400
Main coil
Water entering/leaving connections
(type)
ISO R7 rotating female
(Dia)
3/4"
3/4"
1 1/2"
1 1/2"
1 1/2"
Electric heater (accessory for blower only)
Electric power supply
(V/Ph/Hz)
230/1/50
230/1/50 or 400/3/50
400/3/50
400/3/50
400/3/50
Heating capacity
(kW)
2/4
8
10
12
12
Hot water coil (accessory for blower only)
Heating capacity (4)
(kW)
6,3
12
17,4
22,4
34,5
G2 filter (filter box accessory)
Quantity
2
2
2
2
2
Dimensions ( LxWxth)
(mm)
386x221x8
486x271x8
586x321x8
586*421*8
586*621*8
G4 filter (filter box accessory)
Quantity
-
2
2
2
2
Dimensions ( LxWxth)
(mm)
-
486x264x48
586x314x48
586*414*48
586*614*48
Condensate pump (accessory)
(type)
Centrifugal
Water flow - lift height
(l/h - mm)
24 - 500
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5)
(dB(A))
36/40/43
38/41/44
46/50/53
47/52/57
47/52/58
Sound power level (5)
(dB(A))
46/50/53
48/51/54
56/60/63
57/62/67
57/62/68
Unit dimensions
Width x Depth
(mm)
890 x 600
1090 x 710
1290 x 820
1290 x 970
1290 x 1090
Height
(mm)
250
300
350
450
650
Shipped unit dimensions
Width x Depth
(mm)
933 x 644
1133 x 754
1333 x 864
1333 x 1008
1333*1133
Height
(mm)
260
310
360
460
660
Weight
(kg)
32
46
61
76
118
Colour
galvanised steel
Recommended fuse size
Unit alone (aM/gI)
(A)
8/16
8/16
8/16
8/25
8/25
Unit with electric heater (gI)
(A)
16 (2kW),25 (4kW)
40 (230V),3*16 (400V)
3*20
3*25
3*25
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
CG-SVX051A-GB
66
As a commitment to our customers, we have created a wide service network staffed with experienced factory-
authorized technicians. At Trane we offer all the benefits of after sales service direct from the manufacturer and we
are committed to our mission statement to provide efficient customer care.
We would be delighted to discuss your individual requirement with you. For further information regarding Trane
maintenance agreements please contact your local TRANE sales office.
Year
Commis-
sioning
Inspec-
tion visit
Seasonal
shut
down
Seasonal
start up
Oil
analysis
(2)
Vibration
analysis
(3)
Annual
mainte-
nance
Preven-
tive
mainte-
nance
Tube
analysis
(1)
Com-
pressor
R’newal
(4)
1
x
x
x
x
x
xx
2
x
x
x
x
xxx
3
x
x
x
x
xxx
4
x
x
x
x
xxx
5
x
x
x
x
x
xxx
x
6
x
x
x
x
x
xxx
7
x
x
x
x
x
xxx
8
x
x
x
x
x
xxx
9
x
x
x
x
x
xxx
10
x
x
x
x
x
xxx
x
over 10
every
year
every
year
every
year (2)
x
every
year
every 3
year
every 3
years
40000 h
This timetable is applicable to units operating in normal conditions with an average of 4000 hours per year. If
operating conditions are abnormally severe, an individual timetable must be made for that unit.
(1)
Tube testing required if aggressive water conditions exist. Applies to condensers only on water cooled units.
(2)
Schedule as per previous analysis result or at least once a year.
(3)
Year 1 to define equipment baseline. Subsequent year based on oil analysis results or schedule as per
vibration analysis.
(4)
Recommended at 40 000 run hours or 100 000 equivalent operating hours whichever comes first.
Schedule also depends on results from oil analysis / vibration analysis.
Seasonal start up and shutdown are mainly recommended for Comfort Air Conditioning and annual and preventive
maintenance are mainly recommended for Process application.
Recommended service routine frequencies