11
UNT-PRC002-GB
Sound power levels
Discharge
Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
Fan
Power level in dB(A), per Hz frequency band
Overall power
Unit
speed
125
250
500
1000
2000
4000
8000
dB(A)
1
55
50
42
37
37
31
30
46
FWD 08
2
57
54
47
40
30
38
40
50
3
58
57
50
42
32
40
43
53
1
57
51
45
42
34
33
28
48
FWD 10
2
58
54
48
45
38
39
35
51
3
60
58
50
48
40
42
39
54
1
57
51
45
42
34
33
28
48
FWD 12
2
58
54
48
45
38
39
35
51
3
60
58
50
48
40
42
39
54
1
56
62
50
48
39
38
36
56
FWD 14
2
61
66
55
53
47
46
45
60
3
63
69
58
56
50
50
49
63
1
57
63
51
49
40
39
37
57
FWD 20
2
61
66
55
53
47
46
45
60
3
63
69
58
56
50
50
49
63
Intake
Measurement conditions:
Measurements taken at the horizontal air intake.
Fan
Power level in dB(A), per Hz frequency band
Overall power
Unit
speed
125
250
500
1000
2000
4000
8000
dB(A)
1
56
55
55
53
46
45
42
57
FWD 08
2
63
62
60
60
53
53
53
64
3
66
65
63
62
56
55
57
67
1
62
58
55
58
51
48
44
61
FWD 10
2
66
63
60
62
56
55
52
66
3
70
67
63
65
59
59
57
69
1
62
58
55
58
51
48
44
61
FWD 12
2
66
63
60
62
56
55
52
66
3
70
67
63
65
59
59
57
69
1
66
65
65
65
57
50
46
68
FWD 14
2
73
72
69
71
64
59
57
74
3
78
76
73
75
69
64
63
78
1
68
72
64
64
56
52
50
69
FWD 20
2
76
76
68
71
65
61
61
75
3
78
79
71
74
69
66
66
78
CG-SVX051A-GB
65
Log Check Sheet
The operator log sheet are included for use as appropriate, for installation completion verification before Trane Start-
up is scheduled, and for reference during the Trane Start-up.
Operator Log
Sintesis™ Balance CMAF Multi-Pipe Unit with Tracer Symbio™ 800 Controller - Tracer AdaptiView
Reports - Log Sheet
Start
15 minutes
30 minutes
1 hour
Ckt 1
Ckt 2
Ckt 1
Ckt 2
Ckt 1
Ckt 2
Ckt 1
Ckt 2
Circuit Operating Mode (Cooling
/ Heat Pump / Heat Recovery)
EXV Opening (%)
Coil Condenser
Outdoor Temperature
Air flow (%)
Compressor Manifold
Saturated Suction Temperature
(°C)
Saturated Discharge Temperature
(°C)
Discharge Temperature (°C)
Active Suction Superheat
Setpoint (°C)
Suction Superheat (°C)
Compressor Running Status No1
Compressor Running Status No2
Compressor Running Status No3
Chilled water exchanger
Active Chilled Water Setpoint
Entering Water Temperature
Leaving Water Temperature
Water flow Status
Approach Temperature (°C)
Hot water exchanger
Active Hot Water Setpoint
Entering Water Temperature
Leaving Water Temperature
Water flow Status
Refrigerant Pressure (kPa)
Approach Temperature (°C)
Receiver
Saturated Liquid temperature
Active Subcooling Setpoint (°C)
Subcooling (°C)
Drain Valve Opening (%)
Fill Up Valve Opening (%)
Date:
Technician:
Owner: