General Information

Kit Inspection

Upon receipt of the kit, immediately note;

[ ] Any visible damage to the exterior shipping package.

Record any damage on the shipping documents.

Specify the type and extent of the damage on the “bill of
lading” before signing.

[ ] Unpack the contents and carefully inspect it for obvious

damage due to shipment.

[ ] If concealed damage has occurred, notify the carrier’s

terminal of the damage immediately by phone and by
mail. Concealed damage must be reported within 15
days.

[ ] Do not remove damaged material from the receiving lo-

cation. Take photos of the damage, if possible. The
owner must provide reasonable evidence that the dam-
age did not occur after delivery.

[ ] Check for material shortages. Within the package you

should find;

1 - Sensor Module,
1 – Package of mounting hardware, and;
1 - Installation and operation manual.

Contact the Parts Center nearest your area should there be
any damaged or missing components.

Remote Panel w/ NSB - BAYSENS019B
This 7 day programmable sensor features 2,3 or 4 periods
for Occupied or Unoccupied programming per day. If the
power is interrupted, the program is retained in permanent
memory. If power is off for an extended period of time, only
the clock and day may have to be reset.

The Zone Sensor allows selection of four system modes
(Heat, Cool, Auto, and Off), two fan modes (On and Auto). It
has dual temperature selection with programmable start
time capability.

The occupied cooling set point ranges between 45 and 98
degrees Fahrenheit.The heating set point ranges between
43 and 96 degrees Fahrenheit.

A liquid crystal display (LCD) displays zone temperature,
temperature set points, day of the week, time, and opera-
tional mode symbols.

The Option Menu is used to enable or disable applicable
functions, i.e.; Morning Warm-up, Economizer minimum po-
sition override during unoccupied status, Fahrenheit or
Centigrade, Supply air tempering, Remote zone tempera-
ture sensor, 12/24 hour time display, Smart fan, and Com-
puted recovery.

During an occupied period, an auxiliary relay rated for 1.25
amps @ 30 volts AC with one set of single pole double
throw contacts is activated.

Содержание SENS-IN-1D18-HD60D29-4

Страница 1: ...BAYSENS019B 2 25 T Packaged Heat Cool Units ASYSTAT666B 2 20 T Packaged Heat Pump Units 27 5 50 T Packaged Heat Cool Units 20 130 T Packaged Rooftop Units 20 80 T Commercial Self Contained Units PROG...

Страница 2: ...ships inside each Programmable Zone Sensor kit and is customer property The unit s maintenance personnel must retain it This booklet describes step by step instructions for install ing and programmin...

Страница 3: ...ENS019B This 7 day programmable sensor features 2 3 or 4 periods for Occupied or Unoccupied programming per day If the power is interrupted the program is retained in permanent memory If power is off...

Страница 4: ...4 General Information...

Страница 5: ...in place and mark the three holes Drill three 3 16 inch 4 8 mm holes Gently tap the plastic anchors into the holes until they are flush with the wall Level the sub base and firmly tighten the mounting...

Страница 6: ...E SERVICING Failure to disconnect power before servicing can cause severe personal injury or death Connecting the wires 1 Strip approximately inch of insulation from each wire and connect the wiring t...

Страница 7: ...7 Installation Figure 3 Zone Sensor Connection Diagram...

Страница 8: ...ied or set Refer to the Normal Run State screen To set the time simply press the or side of the KEY marked TIME Press the positive side to advance the time in one minute intervals Press the negative s...

Страница 9: ...enu Pressing the TIME and KEY changes the option value associated with each option number Refer to the Option Menu Screen illustration and the ZSM options and option values table with a description of...

Страница 10: ...ammed If 4 is selected Morn Day Eve and Nite can be programmed 10 Programmable Fan Operation 0 Disallowed 1 Allowed 0 If allowed Supply Fan operation can be programmed for On or Auto operation for eac...

Страница 11: ...OCCUPIED 8 Press the FAN KEY to program the fan to be either ON or AUTO for this period Note This feature will not be available if option 10 in the OPTIONS MENU has been set to 0 9 Pressing the ERASE...

Страница 12: ...12 Programming And Operation...

Страница 13: ...Cool Set Point Occupied Unoccupied Morn Occ Unocc Day Occ Unocc Eve Occ Unocc Nite Occ Unocc Friday Start Time Heat Set Point Cool Set Point Occupied Unoccupied Morn Occ Unocc Day Occ Unocc Eve Occ U...

Страница 14: ...r of days 4 Press the UP or DOWN arrows to program the tem perature set points HEAT and or COOL Use the MODE KEY to toggle between the Modes if applicable 5 Press the FAN KEY to program the fan for ON...

Страница 15: ...15 Programming And Operation...

Страница 16: ...16 Programming And Operation...

Страница 17: ...rminal 8 COOL Icon ON Indicates by a continuously illuminated icon that the unit is operating in the Cooling Mode FLASHING The COOL FAILURE icon indicates that a system failure in the Cooling Mode has...

Страница 18: ...ndition 2 If Option 11 in the Options Menu is set to 0 then the local thermistor is selected and the on board thermistor is open and rhe ZSM must be replaced Zone Temperature is not displayed Verify t...

Страница 19: ...19...

Страница 20: ...20...

Отзывы: