28
SSA-SVX06H-EN
N
NO
OT
TIIC
CE
E
U
Usse
e C
Co
op
pp
pe
err C
Co
on
nd
du
ucctto
orrss O
On
nlly
y!!
F
Fa
aiillu
urre
e tto
o u
usse
e cco
op
pp
pe
err cco
on
nd
du
ucctto
orrss cco
ou
ulld
d rre
essu
ulltt iin
n
e
eq
qu
uiip
pm
me
en
ntt d
da
am
ma
ag
ge
e a
ass tth
he
e e
eq
qu
uiip
pm
me
en
ntt w
wa
ass n
no
ott
d
de
essiig
gn
ne
ed
d o
orr q
qu
ua
alliiffiie
ed
d tto
o a
acccce
ep
ptt o
otth
he
err tty
yp
pe
ess o
off
cco
on
nd
du
ucctto
orrss..
Symbio™ Controls
Wiring shown with dashed lines is to be furnished and
installed by the customer. All customer supplied wiring
must be copper only and must conform to NEC and
local electrical codes. Codes may require line of sight
between disconnect switch and unit.
Figure 22.
Symbio™ jobsite connections
Zone
Sensor
T’stat
Air Handler
Disconnect Switch
(By Others)
Disconnect Switch
(By Others) Note 1
Electric
Heat Accessory
Disconnect Switch
(By Others)
Note 1
B
A
B
D
E
C
P
Po
ow
we
err W
Wiirre
ess
A. 3 wires, line voltage for 3 phase, (2 wires for single
phase) 1 grounding wire
B. 3 wires, line voltage for 3 phase, (2 wires for single
phase) 1 grounding wire
C
Co
on
nttrro
oll W
Wiirre
ess
C. Cooling only (or Cooling with Heat) thermostat: 4 to
7 wires depending on stages of cooling and electric
heat
C. Heat Pump thermostat: 6 to 9 wires depending on
T’stat options and stages of cooling and heating
D. Wiring between indoor and outdoor unit: 5 to 11
wires depending on unit control options*
E. Zone Sensor: 4 to 7 wires depending on zone sensor
model*
*Communication signal wires require twisted pairs.
Refer to unit schematics for identification of twisted
pairs.
N
No
otte
ess::
1. When electric heater accessory is used,
single point power entry or dual point power
entry is field optional. Single point power
entry option is through electric heater only.
2. ***Choose only one of the following;
Thermostat, Mechanical Zone Sensor,
Programmable Zone Sensor Panel or BAS
Zone Sensor.
IIm
mp
po
orrtta
an
ntt:: For the EDC switch to be functional and
thereby facilitate reliable unit operation,
make the EDC connections from the indoor
to the outdoor control boxes.
Table 5. Recommended thermostat wire size
Wire Size
Maximum Wire Length
(Gauge)
Physical distance between Unit & T’stat
22
30 Feet
20
50 Feet
18
75 Feet
16
125 Feet
14
200 Feet
Table 6. Zone sensor module wiring
Distance from Unit to
Control
Recommended Wire Size
0-150 feet (0-45.7 m)
22 gauge (0.33 mm
2
)
151-240 feet (46-73.1 m)
20 gauge (0.50 mm
2
)
241-305 feet (73.5-117.3 m)
10 gauge (0.75 mm
2
)
386-610 feet (117.7-185.9
111)
16 gauge (1.3 mm
2
)
611-970 feet (186.2-295.7 m)
14 gauge ( 2.0 mm
2
)
Installation Checklist
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
Complete this checklist once the unit is installed to
verify that all recommended procedures have been
accomplished before the system is started. Operational
checks cannot be performed until the outdoor unit is
installed and system interconnection is complete.
☐
Verify that the unit electrical power is disconnected.
IIn
nsstta
alllla
attiio
on
n