![Trane AquaStream 2 CCUN Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/trane/aquastream-2-ccun-series/aquastream-2-ccun-series_installation-operation-and-maintenance_1149617007.webp)
7
CG-SVX06F-GB
General Data
Table 1 - General data - CGWN/CCUN R410A
Unit size
205
206
207
208
209
210
211
212
213
214
215
Standard Efficiency
Cooling mode
Net Capacity
(kW)
182.0
216.0
251.0
283.1
282.0
311.0
341.0
411
444
477
506
Evaporator water pressure drop
(kPa)
57.6
59.0
55.6
42
42.4
41.8
49.8
44
43
43
42
Evaporator head pressure
available (6)
(kPa)
161
141
142
149
143
188
176
224
212
214
204
Condenser water pressure drop
(kPa)
59
65
61
47
47.9
52.8
63.4
64
74
73
82
Condenseur head pressure
available (6)
(kPa)
151
134
138
162
150
132
117
173
161
157
143
Heating mode
Net Capacity
(kW)
214
254.8
296.2
329.1
362.0
400.8
441.8
478.9
518.1
557.3
591.2
Evaporator water pressure drop
(kPa)
46
47
45
34
30
40
48
50
50
50
49
Evaporator head pressure
available (6)
(kPa)
182
167
156
163
160
204
193
250
229
217
205
Condenser water pressure drop
(kPa)
54
60
56
44
48
51
62
57
65
65
73
Condenseur head pressure
available (6)
(kPa)
157
141
159
167
158
140
124
193
182
169
156
High Efficiency
Cooling mode
Net Capacity
(kW)
193.0
227.0
262.0
-
-
-
-
-
-
-
-
Evaporator water pressure drop
(kPa)
26.1
35.7
36.6
-
-
-
-
-
-
-
-
Evaporator head pressure
available (6)
(kPa)
188
156
160
-
-
-
-
-
-
-
-
Condenser water pressure drop
(kPa)
31
43
41
-
-
-
-
-
-
-
-
Condenseur head pressure
available (6)
(kPa)
177
154
173
-
-
-
-
-
-
-
-
Heating mode
Net Capacity
(kW)
221
262
303
-
-
-
-
-
-
-
-
Evaporator water pressure drop
(kPa)
21
28
29
-
-
-
-
-
-
-
-
Evaporator head pressure
available (6)
(kPa)
203
180
170
-
-
-
-
-
-
-
-
Condenser water pressure drop
(kPa)
28
39
38
-
-
-
-
-
-
-
-
Condenseur head pressure
available (6)
(kPa)
180
159
177
-
-
-
-
-
-
-
-
System Data
Refrigerant circuit
2
2
2
2
2
2
2
2
2
2
2
Capacity steps
4
4
4
4
4
4
4
6
6
6
6
Minimum capacity
%
25
21
25
22
25
23
25
17
17
17
17
Units Amps (2) (4)
Nominal (3)
(A)
131
146
161
182
203
219
235
262
282
303
319
Start-up Amps
Standard unit
(A)
259
321
336
392
413
481
497
472
492
513
581
With soft starter option
(A)
195
235
250
288
309
353
369
368
388
409
453
Short circuit unit capacity
(kA)
15
15
15
15
15
15
15
15
15
15
15
Max supply cable size
(mm2)
150
150
150
150
240
240
240
240
240
240
240
Compressor
Number
4
4
4
4
4
4
4
6
6
6
6
Type
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Model
(15T+15T) (15T+20T) (20T+20T) (20T+25T) (25T+25T) (25T+30T) (30T+30T)
(20T+
20T+25T)
(25T+
20T+25T)
(25T+
25T+25T)
(25T+
25T+30T)
Number of speeds
1
1
1
1
1
1
1
1
1
1
1
Number of motors
1
1
1
1
1
1
1
1
1
1
1
Rated Amps (comp A/B/C) (5)
(A)
32/32
32/40
40/40
40/50
50/50
50/58
58/58
40/40/50 50/40/50 50/50/50 50/50/58
Locked rotor Amps (comp A/B/C)
(A)
160/160
160/215
215/215
215/260
260/260
260/320
320/320
215/
215/260
260/
215/260
260/
260/260
260/
260/320
Motor RPM
(rpm)
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
Power factor (comp A/B/C)
0,81/0,81 0,81/0,87 0,87/0,87 0,87/0,86 0,86/0,86 0,86/0,89 0,89/0,89
0,87/
0,87/0,86
0,86/
0,87/0,86
0,86/
0,86/0,86
0,86/
0,86/0,89
Sump Heater (comp A/B/C)
(W)
160/160
160/160
160/161
160/162
160/163
160/164
160/165
160/
160/160
160/
160/160
160/
160/161
160/